Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions



Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions



Current Eye Research 40(9): 923-929



To compare intraocular pressure (IOP) measurements obtained using the Icare Pro rebound tonometer and Tono-Pen XL tonometer in supine and lateral decubitus body positions. One-hundred eyes of 50 subjects (normal volunteers or glaucoma suspects) were enrolled in this prospective observational study. IOP was measured in both eyes using the Icare Pro and Tono-Pen XL in the sitting position and the recumbent positions including supine, right lateral decubitus and left lateral decubitus. IOP was measured five minutes after assuming each of the recumbent postures in a randomized sequence. The eye on the lower side in the lateral decubitus position was termed as the dependent eye. Agreement of IOP readings between the Icare Pro and Tono-Pen was assessed in all recumbent positions. Differences of IOP readings (ΔIOP) between the two tonometers and their correlations with ocular parameters were also assessed in all positions. The IOP readings obtained using Icare Pro and Tono-Pen showed good correlations in supine and lateral decubitus positions (all r > 0.7, p < 0.005), although Icare Pro readings were higher than Tono-Pen readings (all p < 0.001) in all positions. The ΔIOP showed a weakly positive correlation with central corneal thickness in both eyes, whereas such a positive correlation was found only in the dependent eye in the lateral decubitus positions (r = 0.307-0.531, all p < 0.005). Both the spherical equivalents and axial lengths were not correlated with ΔIOP in all positions. IOP readings obtained with Tono-Pen and Icare Pro tonometers showed good agreement in supine as well as in lateral decubitus positions, although Icare readings were higher than Tono-Pen readings in all positions. Such differences in IOP readings between the different tonometers need to be considered when measuring IOPs in various body positions.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052226740

Download citation: RISBibTeXText

PMID: 25271991

DOI: 10.3109/02713683.2014.964416


Related references

Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects. Journal of Glaucoma 24(8): 613-618, 2016

Comparison of the Intraocular Pressure Measured Using the New Rebound Tonometer Icare ic100 and Icare TA01i or Goldmann Applanation Tonometer. Journal of Glaucoma 28(2): 172-177, 2019

Comparison of intraocular pressure measurements and assessment of intraobserver and interobserver reproducibility with the portable ICare rebound tonometer and Goldmann applanation tonometer in glaucoma patients. Journal of Glaucoma 22(4): 325-329, 2013

Diagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients. Diagnosis 2(4): 227-234, 2015

Comparability of Icare Pro Rebound Tonometer with Goldmann Applanation and Noncontact Tonometer in a Wide Range of Intraocular Pressure and Central Corneal Thickness. Ophthalmic Research 54(1): 18-25, 2016

Intradevice and Interdevice Agreement Between a Rebound Tonometer, Icare PRO, and the Tonopen XL and Kowa Hand-held Applanation Tonometer When Used in the Sitting and Supine Position. Journal of Glaucoma 24(7): 515-521, 2016

Comparison of measurement of intraocular pressure by ICARE PRO® tonometer and Goldman applanation tonometer. Ceska a Slovenska Oftalmologie 70(3): 90-93, 2015

Comparison of Intraocular Pressure Measurement with Schiotz Tonometer and Tono-Pen Vet Tonometer in Healthy Dogs. Journal of Veterinary Research 62(2): 243-247, 2018

Reliability and reproducibility of introcular pressure (IOP) measurement with the Icare ® Home rebound tonometer (model TA022) and comparison with Goldmann applanation tonometer in glaucoma patients. Journal Francais d'Ophtalmologie 40(10): 865-875, 2017

The influence of the tonometer position on canine intraocular pressure measurements using the Tonovet ® rebound tonometer. Open Veterinary Journal 8(1): 68-76, 2018

Evaluation of intraocular pressure measurements obtained by use of a rebound tonometer and applanation tonometer in dogs before and after elective phacoemulsification. American Journal of Veterinary Research 73(5): 709-713, 2012

Measurement of the difference in intraocular pressure between the sitting and lying body positions in healthy subjects: direct comparison of the Icare Pro with the Goldmann applanation tonometer, Pneumatonometer and Tonopen XL. Clinical and Experimental Ophthalmology 42(7): 608-614, 2015

Non-invasive determination of intraocular pressure in the rat eye Comparison of an electronic tonometer , and a rebound tonometer. Graefe's Archive for Clinical & Experimental Ophthalmology 240(11): 942-946, 2002

Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions. Bmc Ophthalmology 13: 44, 2014

Evaluation of a New Rebound Self-tonometer, Icare HOME: Comparison With Goldmann Applanation Tonometer. Journal of Glaucoma 26(7): 613-618, 2017