Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis



Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis



Acta Radiologica 52(10): 1101-1106



Tube current is an important determinant of radiation dose and image quality in X-ray-based examination. The combined automatic tube current modulation technique (ATCM) enables automatic adjustment of the tube current in various planes (x-y and z) based on the size and attenuation of the body area scanned. To compare image quality and radiation dose of the ATCM with those of a fixed tube current technique (FTC) in CT of the abdomen and pelvis performed with a 16-slice multidetector row CT. We reviewed 100 patients in whom initial and follow-up CT of the abdomen and pelvis were performed with FTC and ATCM. All acquisition parameters were identical in both techniques except for tube current. We recorded objective image noise in liver parenchyma, subjective image noise and diagnostic acceptability by using a five-point scale, radiation dose, and body mass index (BMI, kg/m(2)). Data were analyzed with parametric and non-parametric statistical tests. There was no significant difference in image noise and diagnostic acceptability between two techniques. All subjects had acceptable subjective image noise in both techniques. The significant reduction in radiation dose (45.25% reduction) was noted with combined ATCM (P < 0.001). There was a significant linear statistical correlation between BMI and dose reduction (r = -0.78, P < 0.05). The ATCM for CT of the abdomen and pelvis substantially reduced radiation dose while maintaining diagnostic image quality. Patients with lower BMI showed more reduction in radiation dose.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052235878

Download citation: RISBibTeXText

PMID: 21903869

DOI: 10.1258/ar.2011.100295


Related references

Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography. Ajnr. American Journal of Neuroradiology 30(9): 1754-1759, 2009

Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 232(2): 347-353, 2004

Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. Ajr. American Journal of Roentgenology 186(3): 673-679, 2006

Quantitative assessment of image noise and streak artifact on CT image: comparison of z-axis automatic tube current modulation technique with fixed tube current technique. Computerized Medical Imaging and Graphics 33(5): 353-358, 2009

Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. Ajnr. American Journal of Neuroradiology 27(10): 2221-2225, 2006

Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol. Journal of Cardiovascular Computed Tomography 6(3): 184-190, 2012

Whole-body CT with high heat-capacity X-ray tube and automated tube current modulation--effect of tube current limitation on contrast enhancement, image quality and radiation dose. European Journal of Radiology 84(5): 877-883, 2015

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997, 2009

Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Investigative Radiology 54(5): 265-272, 2019

Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation. International Journal of Cardiovascular Imaging 29(Suppl. 1): 47-51, 2013

Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D). Plos one 10(11): E0142185, 2015

Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?. Emergency Radiology 24(1): 31-37, 2017

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. Journal of X-Ray Science and Technology 21(4): 453-464, 2013

Ultra-low dose CT colonography with automatic tube current modulation and sinogram-affirmed iterative reconstruction: Effects on radiation exposure and image quality. Journal of Applied Clinical Medical Physics 20(1): 321-330, 2019

Estimated Patient Dose Indexes in Adult and Pediatric MDCT: Comparison of Automatic Tube Voltage Selection With Fixed Tube Current, Fixed Tube Voltage, and Weight-Based Protocols. Ajr. American Journal of Roentgenology 205(3): 592-598, 2015