+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography



Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography



Ajnr. American Journal of Neuroradiology 30(9): 1754-1759



The combined automatic tube current modulation (ATCM) technique adapts and modulates the x-ray tube current in the x-y-z axis according to the patient's individual anatomy. We compared image quality and radiation dose of the combined ATCM technique with those of a fixed tube current (FTC) technique in craniocervical CT angiography performed with a 64-section multidetector row CT (MDCT) system. A retrospective review of craniocervical CT angiograms (CTAs) by using combined ATCM (n = 25) and FTC techniques (n = 25) was performed. Other CTA parameters, such as kilovolt (peak), matrix size, FOV, section thickness, pitch, contrast agent, and contrast injection techniques, were held constant. We recorded objective image noise in the muscles at 2 anatomic levels: radiation exposure doses (CT dose index volume and dose-length product); and subjective image quality parameters, such as vascular delineation of various arterial vessels, visibility of small arterial detail, image artifacts, and certainty of diagnosis. The Mann-Whitney U test was used for statistical analysis. No significant difference was detected in subjective image quality parameters between the FTC and combined ATCM techniques. Most subjects in both study groups (49/50, 98%) had acceptable subjective artifacts. The objective image noise values at shoulder level did not show a significant difference, but the noise value at the upper neck was higher with the combined ATCM (P < .05) technique. Significant reduction in radiation dose (18% reduction) was noted with the combined ATCM technique (P < .05). The combined ATCM technique for craniocervical CTA performed at 64-section MDCT substantially reduced radiation exposure dose but maintained diagnostic image quality.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052235879

Download citation: RISBibTeXText

PMID: 19509074

DOI: 10.3174/ajnr.a1675


Related references

Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis. Acta Radiologica 52(10): 1101-1106, 2011

Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol. Journal of Cardiovascular Computed Tomography 6(3): 184-190, 2012

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997, 2009

Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D). Plos one 10(11): E0142185, 2015

Whole-body CT with high heat-capacity X-ray tube and automated tube current modulation--effect of tube current limitation on contrast enhancement, image quality and radiation dose. European Journal of Radiology 84(5): 877-883, 2015

Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Investigative Radiology 54(5): 265-272, 2019

Quantitative assessment of image noise and streak artifact on CT image: comparison of z-axis automatic tube current modulation technique with fixed tube current technique. Computerized Medical Imaging and Graphics 33(5): 353-358, 2009

Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation. International Journal of Cardiovascular Imaging 29(Suppl. 1): 47-51, 2013

Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. Ajnr. American Journal of Neuroradiology 27(10): 2221-2225, 2006

Automatic tube potential selection with tube current modulation in coronary CT angiography: Can it achieve consistent image quality among various individuals?. Experimental and Therapeutic Medicine 16(1): 253-259, 2018

CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose. Academic Radiology 23(12): 1513-1520, 2016

Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 232(2): 347-353, 2004

Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?. Emergency Radiology 24(1): 31-37, 2017

Step-and-shoot prospectively ECG-gated versus retrospectively ECG-gated with tube current modulation coronary CT angiography using the 128-slice MDCT: comparison of image quality and radiation dose. Acta Radiologica 52(2): 155-160, 2011

Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. Ajr. American Journal of Roentgenology 186(3): 673-679, 2006