Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging



Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging



Medical Physics 38(1): 23-33



To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/ rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full-field imaging by 259%, 279%, and 145% for SEDR, slot-scan, and full-field with grid, respectively. The average CNR over four regions was found to improve over that for nongrid full-field imaging by 201% for SEDR as compared to 133% for the slot-scan technique and 14% for the antiscatter grid method. Both SEDR and slot-scan techniques outperformed the antiscatter grid method used in standard full-field radiography. For imaging with the same effective exposure, the SEDR technique offers no advantage over the slot-scan method in terms of SPRs and CRs. However, it improves CNRs significantly, especially in heavily attenuating regions. The improvement of low-contrast performance may help improve the detection of the lung nodules or other abnormalities and may offer SEDR the potential for dose reduction in chest radiography.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052242544

Download citation: RISBibTeXText

PMID: 21361171

DOI: 10.1118/1.3519903


Related references

Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study. Medical Physics 35(6): 2391-2402, 2008

Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems. Radiology 235(3): 940-949, 2005

Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images. Medical Physics 34(7): 2718-2729, 2007

Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography for detection of simulated nodules and interstitial disease in a chest phantom. Radiology 231(1): 156-163, 2004

Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography: comparison of image quality in a phantom study. Radiology 235(3): 857-866, 2005

Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience. Physics in Medicine and Biology 54(22): 6959-6978, 2009

Slot-scan digital radiography of the lower extremities: a comparison to computed radiography with respect to image quality and radiation dose. Korean Journal of Radiology 10(1): 51-57, 2009

Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems--a contrast-detail phantom study. Medical Physics 28(11): 2328-2335, 2001

Optimization of X-ray conditions for full spine X-ray examinations in slot-scan digital radiography. Nihon Hoshasen Gijutsu Gakkai Zasshi 67(11): 1438-1442, 2011

Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study. British Journal of Radiology 73(873): 963-968, 2000

Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index. European Radiology 12(9): 2381-2387, 2002

Comparison of Radiation Exposure to the Patient and Contrast Detail Resolutions Across Low Dose 2d/3d Slot Scanner and two Conventional Digital Radiography X-Ray Imaging Systems. Radiation Protection Dosimetry 2019:, 2019

Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography. Ajr. American Journal of Roentgenology 181(4): 923-929, 2003

Digital radiography versus conventional radiography in chest imaging: diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study. Ajr. American Journal of Roentgenology 174(1): 75-80, 2000

Optimizing Image Quality, Radiation Dosage to the Patient and to the Detector in Pediatric Chest Radiography: a Phantom Study of a Portable Digital Radiography System. Radiation Protection Dosimetry 2019:, 2019