Comprehensive Assessment of Degradation Behavior of Aspirin and Atorvastatin Singly and in Combination by Using a Validated RP-HPLC Method



Comprehensive Assessment of Degradation Behavior of Aspirin and Atorvastatin Singly and in Combination by Using a Validated RP-HPLC Method



Scientia Pharmaceutica 81(1): 195-210



A fixed-dose combination of atorvastatin and aspirin is widely used for the treatment of myocardial infarction. The present work describes a comprehensive study of the stress degradation behavior of atorvastatin and aspirin alone as well as in combination of 1:1 and 1:7.5 ratios, respectively, as per ICH guidelines. The degradation products of aspirin as well as atorvastatin were successfully separated by a developed simple, selective, and precise stability-indicating reversed-phase HPLC method. Chromatographic separation was achieved on the Phenomenex Luna analytical column, 150 mm × 4.6 mm, 5μm. The mobile phase consisted of 0.1% glacial acetic acid in water and acetonitrile in the ratio of 50:50 v/v at a flow rate of 1.0 ml/min. UV detection was performed at 246 nm. The extent of degradation was significantly influenced when both of the drugs were present in combination. Stress degradation behavior of atorvastatin was highly influenced by aspirin under acid hydrolysis, thermal degradation, and oxidative stress conditions. Similarly, the stress degradation behavior of aspirin was affected by atorvastatin especially under neutral hydrolysis, thermal degradation, and oxidative stress conditions. Additionally, the combination ratio of aspirin and atorvastatin also influenced the percentage degradation of each other. A mixture of aspirin and atorvastatin was also analyzed after a one-month stability study at 40 °C and 75% RH. All the results indicate chemical incompatibility of both aspirin and atorvastatin if present in combination.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052269576

Download citation: RISBibTeXText

PMID: 23641338

DOI: 10.3797/scipharm.1210-19


Related references

Validation of RP-HPLC method and stress degradation for the combination of metformin HCl, atorvastatin calcium and glimepiride: application to nanoparticles. Journal of Chromatographic Science 53(10): 1654-1662, 2016

Optimization and establishment of a validated stability-indicating HPLC method for study of the stress degradation behavior of metoprolol succinate. Journal of Aoac International 93(3): 911-916, 2010

Stress Degradation Behavior of Atorvastatin Calcium and Development of a Suitable Stability-Indicating LC Method for the Determination of Atorvastatin, its Related Impurities, and its Degradation Products. Scientia Pharmaceutica 81(1): 93-114, 2013

Development of Validated Bioanalytical HPLC-UV Method for Simultaneous Estimation of Amlodipine and Atorvastatin in Rat Plasma. Indian Journal of Pharmaceutical Sciences 77(6): 742-750, 2016

Validated HPLC-MS-MS method for simultaneous determination of atorvastatin and 2-hydroxyatorvastatin in human plasma-pharmacokinetic study. Analytical and Bioanalytical Chemistry 386(2): 275-285, 2006

HPLC and LC-MS studies on stress degradation behaviour of tinidazole and development of a validated specific stability-indicating HPLC assay method. Journal of Pharmaceutical and Biomedical Analysis 34(1): 11-18, 2004

New Validated Stability-Indicating Rp-HPLC Method for Simultaneous Estimation of Atorvastatin and Ezetimibe in Human Plasma by Using PDA Detector. Advanced Pharmaceutical Bulletin 5(3): 385-391, 2015

Concurrent Estimation of Clopidogrel Bisulfate and Aspirin in Tablets by Validated RP-HPLC Method. Indian Journal of Pharmaceutical Sciences 70(5): 667-669, 2008

New Validated RP-HPLC Analytical Method for Simultaneous Estimation of Atorvastatin and Ezetimibe in Bulk Samples as Well in Tablet Dosage Forms by Using PDA Detector. Current Drug Discovery Technologies 11(4): 259-270, 2015

Stress degradation studies on azithromycin and development of a validated stability-indicating TLC-densitometric method with HPLC/electrospray ionization-MS analysis of degradation products. Journal of Aoac International 95(5): 1418-1424, 2012

A Fast and Validated Reversed-Phase HPLC Method for Simultaneous Determination of Simvastatin, Atorvastatin, Telmisartan and Irbesartan in Bulk Drugs and Tablet Formulations. Scientia Pharmaceutica 86(1): -, 2017

Validated stability-indicating reversed-phase-HPLC method for simultaneous determination of orphenadrine citrate, caffeine and aspirin. Chemical & Pharmaceutical Bulletin 60(11): 1426-1436, 2013

Validated Stability-Indicating Reversed-Phase-HPLC Method for Simultaneous Determination of Orphenadrine Citrate, Caffeine and Aspirin. Chemical & Pharmaceutical Bulletin 60(11): 1426-1436, 2012

Degradation Study on Sulfasalazine and a Validated HPLC-UV Method for its Stability Testing. Scientia Pharmaceutica 82(2): 295-306, 2014

Development and Validation of a Reversed-phase HPLC Method for Simultaneous Determination of Aspirin, Atorvastatin Calcium and Clopidogrel Bisulphate in Capsules. Indian Journal of Pharmaceutical Sciences 73(1): 23-29, 2011