+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Comprehensive analysis of proton range uncertainties related to patient stopping-power-ratio estimation using the stoichiometric calibration



Comprehensive analysis of proton range uncertainties related to patient stopping-power-ratio estimation using the stoichiometric calibration



Physics in Medicine and Biology 57(13): 4095-4115



The purpose of this study was to analyze factors affecting proton stopping-power-ratio (SPR) estimations and range uncertainties in proton therapy planning using the standard stoichiometric calibration. The SPR uncertainties were grouped into five categories according to their origins and then estimated based on previously published reports or measurements. For the first time, the impact of tissue composition variations on SPR estimation was assessed and the uncertainty estimates of each category were determined for low-density (lung), soft, and high-density (bone) tissues. A composite, 95th percentile water-equivalent-thickness uncertainty was calculated from multiple beam directions in 15 patients with various types of cancer undergoing proton therapy. The SPR uncertainties (1σ) were quite different (ranging from 1.6% to 5.0%) in different tissue groups, although the final combined uncertainty (95th percentile) for different treatment sites was fairly consistent at 3.0-3.4%, primarily because soft tissue is the dominant tissue type in the human body. The dominant contributing factor for uncertainties in soft tissues was the degeneracy of Hounsfield numbers in the presence of tissue composition variations. To reduce the overall uncertainties in SPR estimation, the use of dual-energy computed tomography is suggested. The values recommended in this study based on typical treatment sites and a small group of patients roughly agree with the commonly referenced value (3.5%) used for margin design. By using tissue-specific range uncertainties, one could estimate the beam-specific range margin by accounting for different types and amounts of tissues along a beam, which may allow for customization of range uncertainty for each beam direction.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052269861

Download citation: RISBibTeXText

PMID: 22678123

DOI: 10.1088/0031-9155/57/13/4095


Related references

Comprehensive analysis of proton range uncertainties related to stopping-power-ratio estimation using dual-energy CT imaging. Physics in Medicine and Biology 62(17): 7056-7074, 2017

Ex vivo validation of a stoichiometric dual energy CT proton stopping power ratio calibration. Physics in Medicine and Biology 63(5): 055016, 2018

Technical Note: On the calculation of stopping-power ratio for stoichiometric calibration in proton therapy. Medical Physics 42(9): 5252-5257, 2015

Ep-1747: Characterizing proton stopping power ratio uncertainties in a Ct/Mri tissue classification model. Radiotherapy and Oncology 127: S936-S937, 2018

Systematic analysis of the impact of imaging noise on dual-energy CT-based proton stopping power ratio estimation. Medical Physics 46(5): 2251-2263, 2019

Regularised patient-specific stopping power calibration for proton therapy planning based on proton radiographic images. Physics in Medicine and Biology 64(6): 065008, 2019

Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiography. Physics in Medicine and Biology 60(5): 1901-1917, 2015

Optimization of the stopping-power-ratio to Hounsfield-value calibration curve in proton and heavy ion therapy. Zeitschrift für Medizinische Physik 25(3): 251-263, 2015

Improved patient-specific optimization of the stopping power calibration for proton therapy planning using a single optimized proton radiography. RadioTherapy and Oncology 118: S62-S63, 2016

OC-0077: Dual energy CT proton stopping power ratio calibration:Validation with animal tissues. RadioTherapy and Oncology 119: S35-S36, 2016

Improved proton stopping power ratio estimation for a deformable 3D dosimeter using Dual Energy CT. RadioTherapy and Oncology 118: S99-S100, 2016

EP-1833: Improved proton stopping power ratio estimation for a deformable 3D dosimeter using Dual Energy CT. RadioTherapy and Oncology 119: S860-S861, 2016

Oc-0086: Validation of proton stopping power ratio estimation based on dual energy Ct using organic tissues. Radiotherapy and Oncology 127: S44-S45, 2018

Validation of proton stopping power ratio estimation based on dual energy CT using fresh tissue samples. Physics in Medicine and Biology 63(1): 015012, 2017

The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power. Physics in Medicine & Biology 43(6): 1579-1592, 1998