Consideration of slice profiles in inversion recovery Look-Locker relaxation parameter mapping



Consideration of slice profiles in inversion recovery Look-Locker relaxation parameter mapping



Magnetic Resonance Imaging 32(8): 1021-1030



To include the flip angle distribution caused by the slice profile into the model used for describing the relaxation curves observed in inversion recovery Look-Locker FLASH T1 mapping for a more accurate determination of the relaxation parameters. For each inversion time, the flip angle dependent signal of the mono-exponential relaxation model is integrated across the slice profile. The resulting Consideration of Slice Profiles (CSP) relaxation curves are compared to the mono-exponential signal model in numerical simulations as well as in phantom and in-vivo experiments. All measured relaxation curves showed systematic deviations from a mono-exponential curve increasing with flip angle and T1 but decreasing with repetition time. Additionally, the accuracy of T1 was found to be largely dependent on the temporal coverage of the relaxation curve. All these systematic errors were largely reduced by the CSP model. The proposed CSP model represents a useful extension of the conventionally used mono-exponential relaxation model. Despite inherent model inaccuracies, the mono-exponential model was found to be sufficient for many T1 mapping situations. However, if only a poor temporal coverage of the relaxation process is achievable or a very precise modeling of the relaxation course is needed as in model-based techniques, the mono-exponential model leads to systematic errors and the CSP model should be used instead.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052307093

Download citation: RISBibTeXText

PMID: 24960366

DOI: 10.1016/j.mri.2014.05.012


Related references

Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit. Journal of Magnetic Resonance Imaging 35(6): 1437-1444, 2012

Inversion group (IG) fitting: A new T1 mapping method for modified look-locker inversion recovery (MOLLI) that allows arbitrary inversion groupings and rest periods (including no rest period). Magnetic Resonance in Medicine 75(6): 2332-2340, 2015

Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magnetic Resonance in Medicine 52(1): 141-146, 2004

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. Journal of Cardiovascular Magnetic Resonance 12(): 69-69, 2011

Assessment of diffuse myocardial fibrosis in rats using small-animal Look-Locker inversion recovery T1 mapping. Circulation. Cardiovascular Imaging 4(6): 636-640, 2012

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer. Magnetic Resonance Imaging 33(4): 363-373, 2016

Automated brain tissue segmentation based on fractional signal mapping from inversion recovery Look-Locker acquisition. Neuroimage 52(4): 1347-1354, 2010

Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners. Journal of Cardiovascular Magnetic Resonance 15(): 64-64, 2013

Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. Journal of Magnetic Resonance Imaging 26(4): 1081-1086, 2007

Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look-locker inversion recovery (MOLLI). Magnetic Resonance in Medicine (): -, 2016

Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging. European Radiology 26(6): 1775-1782, 2015

Fast high-resolution T1 mapping using inversion-recovery Look-Locker echo-planar imaging at steady state: optimization for accuracy and reliability. Magnetic Resonance in Medicine 61(4): 899-906, 2009

Small animal Look-Locker inversion recovery (SALLI) for simultaneous generation of cardiac T1 maps and cine and inversion recovery-prepared images at high heart rates: initial experience. Radiology 261(1): 258-265, 2011

Combining two single-shot imaging techniques with slice-selective and non-slice-selective inversion recovery pulses: new strategy for native MR angiography based on the long T1 relaxation time and inflow properties of blood. Ajr. American Journal of Roentgenology 180(3): 725-728, 2003

Full-brain T1 mapping through inversion recovery fast spin echo imaging with time-efficient slice ordering. Magnetic Resonance in Medicine 54(3): 725-731, 2005