+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Contrast enhancement in chest multidetector computed tomography: intraindividual comparison of 300 mg/ml versus 400 mg/ml iodinated contrast medium



Contrast enhancement in chest multidetector computed tomography: intraindividual comparison of 300 mg/ml versus 400 mg/ml iodinated contrast medium



Academic Radiology 16(2): 144-149



We sought to intraindividually compare intravascular contrast enhancement in multidector computed tomography (MDCT) of the chest using contrast media (CM) containing 300 and 400 mg iodine/ml. Seventy-one patients underwent repeated MDCT scanning of the chest at baseline and follow-up. CM with standard iodine (protocol A: 300 mg iodine/ml; Iopromide 300) and high iodine concentration (protocol B: 400 mg iodine/ml; Iomeprol 400) were used. The iodine delivery rate (1.29 g iodine/s) and total iodine load (37 g iodine) were identical for the two protocols. Contrast enhancement was measured in the right and left ventricles, pulmonary trunk, right and left pulmonary arteries, and ascending and descending aortas. Results were compared using paired t-tests; P values were adjusted using Bonferroni correction (P .005). In the right ventricle, pulmonary trunk, and right and left pulmonary arteries, higher attenuation values for protocol A were detected compared to protocol B (379.0 +/- 110.5 vs. 349.8 +/- 117.6, 354.5 +/- 112.2 vs 330.9 +/- 118.3, 348.6 +/- 106.0 vs. 321.8 +/- 109.9, and 347.9 +/- 102.4 vs. 321.0 +/- 104.9 HU, respectively). After the lung circulation (left ventricle, ascending aorta, and descending aorta), attenuation values were marginally higher for protocol B. Using both protocols resulted in suitable contrast enhancement with a mean pulmonary attenuation higher than 300 HU. Using an adapted injection protocol, the administration of 300 and 400 mg iodine CM resulted in a suitable intravascular contrast enhancement in the chest. The use of 400 mg iodine CM does not lead to a statistically significant improvement in contrast enhancement compared to the 300 mg iodine CM.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052325475

Download citation: RISBibTeXText

PMID: 19124099

DOI: 10.1016/j.acra.2008.05.008


Related references

Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml. European Radiology 18(6): 1199-1205, 2008

Time-course characterization of the computed tomography contrast enhancement of an iodinated blood-pool contrast agent in mice using a volumetric flat-panel equipped computed tomography scanner. Investigative Radiology 41(4): 384-390, 2006

Effect of Tube Voltage on Contrast Enhancement and Contrast Medium Dose in Abdominal Contrast-enhanced Computed Tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi 74(1): 61-67, 2018

Contrast media enhancement in cranial computed tomography --studies of iodinated contrast infusion (ICI). No to Shinkei 28(11): 1225-1233, 1976

Multidetector computed tomography (MDCT) evaluation of myocardial viability: intraindividual comparison of monomeric vs. dimeric contrast media in a rabbit model. European Radiology 19(2): 290-297, 2009

Intraarterial Injection of Iodinated Contrast Medium for Contrast Enhanced Computed Tomography of the Equine Head. Veterinary Radiology and Ultrasound 56(4): 384-390, 2016

Parameters influencing hepatic parenchyma enhancement in x-ray computed tomography after intravenous injection of iodinated contrast medium. Journal de Radiologie 78(4): 265-270, 1997

Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate. European Journal of Radiology 76(1): 135-139, 2010

Quantitative Assessment of Myocardial Enhancement with Iodinated Contrast Medium in Patients with Ischemic Heart Disease by Using Ultrafast X-Ray Computed Tomography. Investigative Radiology 27(6): 436-442, 1992

Quantitative assessment of myocardial enhancement with iodinated contrast medium in patients with ischemic heart disease by using ultrafast x ray computed tomography. Investigative Radiology 27(6): 436-442, 1992

Multidetector helical computed tomography of the liver: comparison of hepatic enhancement using two different contrast media strategies. Academic Radiology 11(3): 267-271, 2004

Contrast enhancement in electron beam tomography of the heart: comparison of a monomeric and a dimeric iodinated contrast agent in 59 patients. Academic Radiology 13(1): 95, 2006

Effects of computed tomography contrast medium factors on contrast enhancement. Nihon Hoshasen Gijutsu Gakkai Zasshi 67(12): 1583-1591, 2011

Contrast enhancement in cerebral computed tomography comparing a nonionic and an ionic contrast medium. Radiology 144(4): 961, 1982

Subtraction images of pre contrast and post contrast medium enhancement body computed tomography scans. Journal of Computer Assisted Tomography 1(3): 362, 1977