Design and static calibration of a six-dimensional force/torque sensor for minimally invasive surgery



Design and static calibration of a six-dimensional force/torque sensor for minimally invasive surgery



Minimally Invasive Therapy and Allied Technologies 23(3): 136-143



The use of surgery robotics is getting more and more important worldwide. In the present study, we propose a novel small-size six-dimensional force/torque sensor with the structure of double cross beams. This technology can be applied in robotic tele-operation systems used in minimally invasive surgery (MIS) robotic systems. The proposed sensor is made of duralumin which totally meets the stiffness requirement. The output voltage of the sensor will alter with the deformation of the elastic body and strain gauges. The feasibility was discussed by finite element analysis (FEA) and the coupling coefficient matrix was established with dimension reduced according to FEA. In addition, we designed a calibration platform and completed static calibration for the sensor. The methods and principles of measurements and data analysis were provided. The calibration curves and coupling coefficient matrix were acquired by using the least squares method (LSM). Experimental tests and calibration error analysis showed that the proposed sensor has high accuracy, appropriate range, and played a role in promoting the application of force feedback technology in MIS.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052503389

Download citation: RISBibTeXText

PMID: 24345276

DOI: 10.3109/13645706.2013.873469


Related references

Active design method for the static characteristics of a piezoelectric six-axis force/torque sensor. Sensors 14(1): 659-671, 2014

Skills evaluation in minimally invasive surgery using force/torque signatures. Surgical Endoscopy 14(9): 791-798, 2000

Surgeon-tool force/torque signatures--evaluation of surgical skills in minimally invasive surgery. Studies in Health Technology and Informatics 62: 290-296, 1999

A robust uniaxial force sensor for minimally invasive surgery. IEEE Transactions on Bio-Medical Engineering 57(5): 1008-1011, 2010

A magnetic force sensor on a catheter tip for minimally invasive surgery. Conference Proceedings 2015: 7970-7973, 2015

Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills. IEEE Transactions on Bio-Medical Engineering 48(5): 579-591, 2001

Grasper integrated tri-axial force sensor system for robotic minimally invasive surgery. Conference Proceedings 2017: 3936-3939, 2017

Use of a Force-Torque Sensor for Self-Calibration of a 6-DOF Medical Robot. Sensors 16(6):, 2016

Advances in bio-tactile sensors for minimally invasive surgery using the fibre Bragg grating force sensor technique: a survey. Sensors 14(4): 6633-6665, 2014

Development of optical fiber Bragg grating force-reflection sensor system of medical application for safe minimally invasive robotic surgery. Review of Scientific Instruments 82(7): 074301, 2011

Evaluation of force data with a force/torque sensor during FESS. A step towards robot-assisted surgery. Hno 56(8): 789-794, 2008

Minimally invasive strabismus surgery versus paralimbal approach: a randomized, parallel design study is minimally invasive strabismus surgery worth the effort?. Indian Journal of Ophthalmology 62(4): 508-511, 2014

An Instrumented Minimally Invasive Surgical Tool: Design and Calibration. Applied Bionics and Biomechanics 8(2): 173-190, 2011

Integration of a miniaturised triaxial force sensor in a minimally invasive surgical tool. IEEE Transactions on Bio-Medical Engineering 53(11): 2397-2400, 2006

Design and Calibration of a Force/Tactile Sensor for Dexterous Manipulation. Sensors 19(4):, 2019