+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Determinants of image quality of Heidelberg Retina Tomography II and its association with optic disc parameters in a population-based setting



Determinants of image quality of Heidelberg Retina Tomography II and its association with optic disc parameters in a population-based setting



American Journal of Ophthalmology 151(4): 663-670



To assess the determinants of image quality of Heidelberg Retina Tomography II (HRT II) and its association with optic disc parameters in a population-based setting. Population-based, cross-sectional study involving 3280 (78.7% response) Asian Malays aged 40 to 80 years. Three thousand fifty-six participants completed the HRT II test. Image quality was assessed using the mean pixel height standard deviation generated by the HRT II, with lower mean pixel height standard deviation indicating higher quality. Participants underwent an interviewer-administered questionnaire and a standardized ophthalmic examination, including visual acuity, applanation tonometry, gonioscopy, refraction, automated perimetry, and lens and fundus photography. The mean (standard deviation) and median of mean pixel height standard deviation in the study population were 34 (34) and 23 μm respectively. In multivariate regression models, older age and the presence of visual impairment, blindness, high myopia, and cataract were significantly associated with greater mean pixel height standard deviation (P<.05 for all). People with a higher mean pixel height standard deviation were more likely to have smaller rim area and greater cup depth. People who are older or have high myopia, visual impairment, blindness, or cataract are more likely to have poor HRT II image quality. Poorer image quality is in turn associated with smaller optic rim area and greater cup depth. These data provide useful information when the HRT instrument is used for diagnosing glaucoma in the general population.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052526494

Download citation: RISBibTeXText

PMID: 21257147

DOI: 10.1016/j.ajo.2010.09.032


Related references

Systemic factors affecting optic disc topographic heidelberg retina tomograph parameters in the general population. ARVO Annual Meeting Abstract Search & Program Planner : Abstract No 3381, 2003

Novel Heidelberg retina tomograph-based morphological parameters derived from optic disc cupping surface processing. Investigative Ophthalmology and Visual Science 52(2): 947-951, 2011

Asymmetry in optic disc morphometry as measured by heidelberg retina tomography in a normal elderly population: the Bridlington Eye Assessment Project. Investigative Ophthalmology & Visual Science 46(11): 4153-4158, 2005

Polar contour-line of optic disc border reaches mean retina height in normal eyes in laser scanning tomography using the Heidelberg retina tomograph. IOVS 42(4): S135, 2001

Automation of morphological optic disc assessment by Heidelberg retina tomography. Investigative Ophthalmology & Visual Science 35(4): 1347, 1994

Characteristics of the optic disc parameters with the Heidelberg Retina Tomograph in normal eyes. IOVS 42(4): S793, 2001

Optic nerve head drusen with and without visual field loss a quantitative analysis of optic disc parameters using heidelberg retinal tomography. ARVO Annual Meeting Abstract Search & Program Planner : Abstract No 615, 2003

Optic disc cup center of gravity and its movement due to glaucoma assessed by Heidelberg retina tomography. Investigative Ophthalmology & Visual Science 35(4): 1347, 1994

Influence of acquisition parameters on hemodynamic measurements with the Heidelberg Retina Flowmeter at the optic disc. Journal of Glaucoma 7(3): 151-157, 1998

Efficacy of mydriasis on the assessment of optic disc stereometric parameters by the heidelberg retina tomograph. ARVO Annual Meeting Abstract Search & Program Planner : Abstract No 3371, 2003

Optic disc analysis with Heidelberg Retina Tomography III in glaucoma with unilateral visual field defects. Japanese Journal of Ophthalmology 54(4): 305-309, 2010

Intraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg Retina Tomograph. Ophthalmology 109(6): 1072-1077, 2002

Normative Topographic Optic Disk Parameters as Measured With the Heidelberg Retina Tomograph in Eyes of a Population-Based Sample of Non Glaucomatous Elderly People. ARVO Annual Meeting Abstract Search & Program Planner : Abstract No 266, 2002

Retinal Nerve Fiber and Optic Disc Morphology in Patients with Human Immunodeficiency Virus Using the Heidelberg Retina Tomography 3. Plos one 10(8): E0133144, 2015