Diaphragm correction factors for free-air chamber standards for air kerma in x-rays



Diaphragm correction factors for free-air chamber standards for air kerma in x-rays



Physics in Medicine and Biology 54(9): 2737-2745



At present, only a correction factor for photon transmission, k(l), is systematically applied for the entrance diaphragm of free-air chamber standards for air kerma. In the present work, the Monte Carlo code PENELOPE is used to re-evaluate k(l) for the BIPM standards and new correction factors are calculated for photon scatter and for fluorescence production in the diaphragm. An additional effect arising from electrons emitted from the diaphragm is shown to be significant at the highest photon energies. The results for the radiation qualities used for international comparisons give a combined diaphragm correction factor k(dia) = 0.9980(3) for the BIPM medium-energy standard at 250 kV. This is significantly different from the factor k(l) = 0.9996(1) in use at present and it might be concluded that differences are likely to exist for all free-air chamber standards. The effect of using a conical taper at the downstream edge of the diaphragm is shown to be negligible for these radiation qualities.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052590671

Download citation: RISBibTeXText

PMID: 19351980

DOI: 10.1088/0031-9155/54/9/009


Related references

Diaphragm correction factors for the FAC-IR-300 free-air ionization chamber. Applied Radiation and Isotopes 132: 178-180, 2018

Effect of the diaphragm of free-air ionisation chamber for X-ray air-kerma measurements. Radiation Protection Dosimetry 146(1-3): 195-197, 2011

Implications of new correction factors on primary air kerma standards in 60 Co-beams. Physics in Medicine and Biology 37(6): 1283-1291, 1992

Correction factors for the NMi free-air ionization chamber for medium-energy x-rays calculated with the Monte Carlo method. Physics in Medicine and Biology 43(11): 3207-3224, 1998

Monte Carlo calculated correction factors for primary standards of air kerma. Medical Physics 30(4): 521-532, 2003

Air kerma calibration factors and chamber correction values for PTW soft x-ray, NACP and Roos ionization chambers at very low x-ray energies. Physics in Medicine and Biology 46(8): 2107-2117, 2001

Air kerma standards for X- and gamma rays and future plans for dosimetric standards at AIST. Nihon Hoshasen Gijutsu Gakkai Zasshi 62(8): 1038-1044, 2006

Monte Carlo calculations of the ionization chamber wall correction factors for 192 Ir and 60 Co gamma rays and 250 kV x-rays for use in calibration of 192 Ir Hdr brachytherapy sources. Physics in Medicine and Biology 44(8): 1897-1904, 1999

Standards of Air Kerma at the BEV for 137Cs Gamma Rays. Radiation Protection Dosimetry 67(4): 291-294, 1996

Monte Carlo calculations of the ionization chamber wall correction factors for 192Ir and 60Co gamma rays and 250 kV x-rays for use in calibration of 192Ir HDR brachytherapy sources. Physics in Medicine and Biology 44(8): 1897-1904, 1999

Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays. Journal of Research of the National Institute of Standards and Technology 114(6): 321-331, 2009

Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays. Journal of Research of the National Institute of Standards and Technology 111(5): 385-391, 2006

Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in 60Co gamma beams. Physics in Medicine and Biology 47(14): 2411-2431, 2002

Investigation of the chamber correction factor ( k ch ) for the Uk secondary standard ionization chamber (Ne2561/Ne2611) using medium-energy x-rays. Physics in Medicine and Biology 43(11): 3195-3206, 1998

Investigation of the chamber correction factor (k(ch)) for the UK secondary standard ionization chamber (NE2561/NE2611) using medium-energy x-rays. Physics in Medicine and Biology 43(11): 3195-3206, 1998