Digital chest radiography image quality assessment with dose reduction



Digital chest radiography image quality assessment with dose reduction



Australasian Physical and Engineering Sciences in Medicine 35(1): 71-80



A retrospective study of digital chest radiography was performed to compare the image quality and dose parameters from two X-ray rooms in different areas of the same hospital using identical X-ray units but different local protocol for obtaining chest PA and lateral radiographs. Image quality of radiographs was assessed from the printed films using well established European guidelines and modified criteria. Patient entrance surface air kerma was calculated using technical data recorded for each radiograph and measured output of the X-ray unit. Effective dose and dose to radiosensitive organs was estimated using dose calculation software PCXMC. There was no statistical significant difference in the evaluated image quality using either technique, median entrance surface air kerma to the patient reduced significantly with added filtration technique and use of normal density setting. Phantom measurements indicated that an additional filtration of 0.1 mm Cu + 1 mm Al in the X-ray beam alone reduced the entrance surface air kerma by 35%.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052624397

Download citation: RISBibTeXText

PMID: 22302464

DOI: 10.1007/s13246-012-0125-5


Related references

Dose reduction in digital chest radiography and perceived image quality. British Journal of Radiology 80(960): 984-988, 2007

A technique for simulating the effect of dose reduction on image quality in digital chest radiography. Journal of Digital Imaging 22(2): 114-125, 2009

Image quality assessment with dose reduction using high kVp and additional filtration for abdominal digital radiography. Physica Medica 50: 46-51, 2018

Image quality of supine chest radiographs: intra-individual comparison of computed radiography and low-dose linear-slit digital radiography. European Radiology 19(9): 2156-2162, 2009

Dose-image quality optimisation in digital chest radiography. Radiation Protection Dosimetry 114(1-3): 269-272, 2005

Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems. Clinical Imaging 36(4): 279-286, 2012

Chest radiography: a comparison of image quality and effective dose using four digital systems. Radiation Protection Dosimetry 114(1-3): 273-277, 2005

The effect of radiation dose reduction on clinical image quality in chest radiography of premature neonates using a dual-side readout technique computed radiography system. Radiation Protection Dosimetry 139(1-3): 275-280, 2010

Dose-image quality study in digital chest radiography using Monte Carlo simulation. Applied Radiation and Isotopes 66(9): 1213-1217, 2008

Assessment of clinical image quality in feline chest radiography with a needle-image plate (NIP) storage phosphor system--an approach to the evaluation of image quality in neonatal radiography. Rofo 182(2): 122-132, 2010

Digital chest radiography: an update on modern technology, dose containment and control of image quality. European Radiology 18(9): 1818-1830, 2008

Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: image quality and potential for dose reduction in comparison with screen-film radiography. Clinical Radiology 55(8): 615-621, 2000

Dose reduction and adequate image quality in digital radiography: a contradiction?. Der Radiologe 52(10): 898-904, 2012

Flat panel digital radiography compared with storage phosphor computed radiography: assessment of dose versus image quality in phantom studies. Investigative Radiology 37(11): 609-614, 2002

Application of a simple phantom in assessing the effects of dose reduction on image quality in chest radiography. Radiography 16(2): 108-114, 2010