+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Does the echogenicity of focal liver lesions on baseline gray-scale ultrasound interfere with the diagnostic performance of contrast-enhanced ultrasound?



Does the echogenicity of focal liver lesions on baseline gray-scale ultrasound interfere with the diagnostic performance of contrast-enhanced ultrasound?



European Radiology 19(5): 1214-1222



The objective was to evaluate whether the echogenicity of focal liver lesions (FLLs) on baseline gray-scale ultrasound (US) interferes with the diagnostic performance of contrast-enhanced US (CEUS) for small FLLs. Three-hundred and eighty-eight patients were examined by real-time CEUS using a sulfur hexafluoride-filled microbubble contrast agent. The images of 114 hyperechoic lesions, 30 isoechoic lesions and 244 hypoechoic lesions were reviewed by two blinded independent readers. A five-point confidence level was used to discriminate malignant from benign lesions, and specific diagnoses were made. The diagnostic performances were evaluated by receiver-operating characteristic (ROC) analysis. The diagnostic performances of CEUS on hyperechoic lesions in terms of the areas (Az) under the ROC curve were 0.987 (reader 1) and 0.981 (reader 2), and were 0.987 (reader 1) and 0.984 (reader 2) for iso- and hypoechoic lesions, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 87.0-95.9%, 93.1-100%, 88.6-100%, 70.0-97.1% and 90.0-95.1%, respectively. The echogenicity of FLLs on baseline gray-scale US does not appear to interfere with the diagnostic ability of CEUS for small FLLs.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052694957

Download citation: RISBibTeXText

PMID: 19137313

DOI: 10.1007/s00330-008-1251-z


Related references

Undetermined focal liver lesions on gray-scale ultrasound in patients with fatty liver: characterization with contrast-enhanced ultrasound. Journal of Gastroenterology and Hepatology 23(10): 1511-1519, 2008

Comparative Diagnostic Performance of Contrast-Enhanced ultrasound versus Baseline Ultrasound for Renal Pelvis Lesions. Ultrasound in Medicine and Biology 41(12): 3109-3119, 2015

Incidental focal solid liver lesions: diagnostic performance of contrast-enhanced ultrasound and MR imaging. European Radiology 20(7): 1715-1725, 2010

Diagnostic performance of contrast-enhanced ultrasound for complex cystic focal liver lesions: blinded reader study. European Radiology 19(2): 358-369, 2009

Characterization of hypoechoic focal hepatic lesions in patients with fatty liver: diagnostic performance and confidence of contrast-enhanced ultrasound. European Radiology 17(3): 650-661, 2007

Solid focal liver lesions indeterminate by contrast-enhanced CT or MR imaging: the added diagnostic value of contrast-enhanced ultrasound. Abdominal Imaging 37(4): 580-590, 2012

Comparison of contrast-enhanced ultrasonography versus baseline ultrasound and contrast-enhanced computed tomography in metastatic disease of the liver: diagnostic performance and confidence. European Radiology 16(7): 1599-1609, 2006

Diagnostic accuracy of contrast-enhanced ultrasound in focal lesions of the liver using cadence contrast pulse sequencing. Ultraschall in der Medizin 27(1): 40-48, 2006

Diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced endoscopic ultrasound (ECEUS) for the differentiation of pancreatic lesions: a systematic review and meta-analysis. Ultraschall in der Medizin 35(6): 515-521, 2014

Heterogeneity in patient diagnostic pathways: an example from contrast-enhanced ultrasound diagnostic scans for focal liver lesions. Bmc Research Notes 7: 199, 2014

Hepatocellular carcinoma diagnostic performance of liver imaging reporting and data system for contrast enhanced ultrasound and of quantitative contrast enhanced ultrasound. Journal of Hepatology 66(1): S220-S221, 2017

Feasibility of dynamic three-dimensional contrast-enhanced ultrasound in focal liver lesions: Image quality evaluation and correlation of quantification with two-dimensional contrast-enhanced ultrasound. Clinical Hemorheology and Microcirculation 72(3): 305-316, 2019

Evaluation of the usefulness of conventional ultrasound and contrast-enhanced ultrasound in characterization of focal liver lesions. Zhongguo Chaosheng Yixue Zazhi 21(12): 924-926, 2005

Characterization of Focal Liver Lesions Indistinctive on B Mode Ultrasound: Benefits of Contrast-Enhanced Ultrasound. Biomed Research International 2017: 8970156, 2017

Contrast-enhanced ultrasound for focal liver lesions. Is it necessary an hepatologist expert in ultrasound techniques in the third millennium?. Liver International 33(10): 1609-1610, 2013