+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Dosimetric comparison of four different external beam partial breast irradiation techniques: three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy



Dosimetric comparison of four different external beam partial breast irradiation techniques: three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy



RadioTherapy and Oncology 90(1): 66-73



As an alternative to whole breast irradiation in early breast cancer, a variety of accelerated partial breast irradiation (APBI) techniques have been investigated. The purpose of our study is to compare the dosimetry of four different external beam APBI (EB-APBI) plans: three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), helical tomotherapy (TOMO), and proton beam therapy (PBT). Thirty patients were included in the study, and plans for four techniques were developed for each patient. A total dose of 30Gy in 6Gy fractions once daily was prescribed in all treatment plans. In the analysis of the non-PTV breast volume that was delivered 50% of the prescribed dose (PD), PBT (mean: 16.5%) was superior to TOMO (mean: 22.8%), IMRT (mean: 33.3%), and 3D-CRT (mean: 40.9%) (p<0.001). The average ipsilateral lung volume percentage receiving 20% of the PD was significantly lower in PBT (0.4%) and IMRT (2.3%) compared with 3D-CRT (6.0%) and TOMO (14.2%) (p<0.001). The average heart volume percentage receiving 20% and 10% of the PD in left-sided breast cancer (N=19) was significantly larger with TOMO (8.0%, 19.4%) compared to 3D-CRT (1.5%, 3.1%), IMRT (1.2%, 4.0%), and PBT (0%, 0%) (p<0.001). All four EB-APBI techniques showed acceptable coverage of the PTV. However, effective non-PTV breast sparing was achieved at the cost of considerable dose exposure to the lung and heart in TOMO.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052705238

Download citation: RISBibTeXText

PMID: 18992950

DOI: 10.1016/j.radonc.2008.09.027


Related references

Adjuvant external beam radiotherapy after therapeutic groin lymphadenectomy for patients with melanoma: a dosimetric comparison of three-dimensional conformal and intensity-modulated radiotherapy techniques. Melanoma Research 27(1): 50-56, 2016

Comparison study of the partial-breast irradiation techniques: dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations. Medical Dosimetry 38(3): 327-331, 2014

Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy. Journal of Medical Physics 40(4): 190-197, 2016

Dosimetric comparison of postoperative whole pelvic radiotherapy for endometrial cancer using three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and helical tomotherapy. Acta Oncologica 49(2): 230-236, 2010

A dosimetric comparison of accelerated partial breast irradiation techniques: multicatheter interstitial brachytherapy, three-dimensional conformal radiotherapy, and supine versus prone helical tomotherapy. International Journal of Radiation Oncology, Biology, Physics 68(3): 935-942, 2007

Dosimetric comparison of proton and photon three-dimensional, conformal, external beam accelerated partial breast irradiation techniques. International Journal of Radiation Oncology, Biology, Physics 65(5): 1572-1578, 2006

Dosimetric comparisons of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and helical tomotherapy in whole abdominopelvic radiotherapy for gynecologic malignancy. Technology in Cancer Research and Treatment 8(5): 369-377, 2009

External beam accelerated partial breast irradiation: dosimetric assessment of conformal and three different intensity modulated techniques. Radiology and Oncology 2019, 2019

High-precision radiotherapy for craniospinal irradiation: evaluation of three-dimensional conformal radiotherapy, intensity-modulated radiation therapy and helical TomoTherapy. British Journal of Radiology 82(984): 1000-1009, 2010

Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy. Radiation Oncology 11: 29, 2016

Can We Spare the Pancreas and Other Abdominal Organs at Risk? A Comparison of Conformal Radiotherapy, Helical Tomotherapy and Proton Beam Therapy in Pediatric Irradiation. Plos One 11(10): E0164643, 2016

New radiotherapy technologies for meningiomas: 3D conformal radiotherapy? Radiosurgery? Stereotactic radiotherapy? Intensity-modulated radiotherapy? Proton beam radiotherapy? Spot scanning proton radiation therapy... or nothing at all?. RadioTherapy and Oncology 71(3): 247-249, 2004

Radiotherapy for esophageal cancer using simultaneous integrated boost techniques: dosimetric comparison of helical TomoTherapy, Volumetric-modulated Arc Therapy (RapidArc) and dynamic intensity-modulated radiotherapy. Technology in Cancer Research and Treatment 12(6): 485-491, 2014

Dosimetric comparison of three-dimensional conformal proton radiotherapy, intensity-modulated proton therapy, and intensity-modulated radiotherapy for treatment of pediatric craniopharyngiomas. International Journal of Radiation Oncology, Biology, Physics 82(2): 643-652, 2012

Radiotherapy for Adult Medulloblastoma: Evaluation of Helical Tomotherapy, Volumetric Intensity Modulated Arc Therapy, and Three-Dimensional Conformal Radiotherapy and the Results of Helical Tomotherapy Therapy. Biomed Research International 2018: 9153496, 2018