+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Effect of cosputtering and sample rotation on improving C60(+) depth profiling of materials



Effect of cosputtering and sample rotation on improving C60(+) depth profiling of materials



Analytical Chemistry 84(21): 9318-9323



In the past decade, buckminsterfullerene (C(60))-based ion beams have been utilized in surface analysis instruments to expand their application to profiling organic materials. Although it had excellent performance for many organic and biological materials, its drawbacks, including carbon deposition, carbon penetration, continuous decay of the sputtering rate, and a rough sputtered surface, hindered its application. Cosputtering with C(60)(+) and auxiliary Ar(+) simultaneously and sample rotation during sputtering were proposed as methods to reduce the above-mentioned phenomena. However, the improvement from these methods has not been compared or studied under identical conditions; thus, the pros and cons of these methods are not yet known experimentally. In this work, a series of specimens including bulk materials and thin films were used to explore the differences between cosputtering and sample rotation on the analytical results. The results show that both of these methods can alleviate the problems associated with C(60)(+) sputtering, but each method showed better improvement in different situations. The cosputtering technique better suppressed carbon deposition, and could be used to generally improve results, especially with continuous spectra acquisition during sputtering (e.g., dynamic secondary ion mass spectrometry (SIMS) depth profiling). In contrast, for the scheme of sputter-then-acquire (e.g., alternative X-ray photoelectron spectrometry or dual-beam static SIMS depth profiling), a better result was achieved by sample rotation because it resulted in a flatter sputtered surface. Therefore, depending on the analytical scheme, a different method should be used to optimize the experimental conditions.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052801027

Download citation: RISBibTeXText

PMID: 23016993

DOI: 10.1021/ac3020824


Related references

Near-surface profiling of semiconductor materials using neutron depth profiling. Semiconductor Science and Technology 10(11): 1423-1431, 1995

Enhanced Surface and In-Depth Characterization of Organic and Inorganic Materials Using XPS and Soft Depth Profiling with Argon Cluster Ion Beams. Microscopy and Microanalysis 18(S2): 918-919, 2012

Depth resolution advantages of plasma sputtering in depth profiling of conductive and non-conductive materials. Surface and Coatings Technology 106(1): 60-65, 1998

Dating Micrometre-Thin Rims Using a LA-ICP-MS Depth Profiling Technique on Zircon from an Archaean Metasediment: Comparison with the SIMS Depth Profiling Method. Geostandards and Geoanalytical Research 38(4): 389-407, 2014

Fast Scanning Laser-OES. II. Sample Material Ablation and Depth Profiling in Metals. Analytical Letters 36(3): 667-677, 2003

ToF-SIMS Depth Profiling of Trehalose: The Effect of Analysis Beam Dose on the Quality of Depth Profiles. Surface and Interface Analysis 43(1-2): 58-61, 2011

Improvement of the gas cluster ion beam-(GCIB)-based molecular secondary ion mass spectroscopy (SIMS) depth profile with O2(+) cosputtering. Analyst 141(8): 2523-2533, 2016

Construction of depth CDP cross section according to materials of multiple seismic profiling. Soviet Geology and Geophysics 22(9): 82-87, 1981

Avoiding coupling fluid-sample interaction in confocal Raman depth Profiling with immersion objectives. Applied Spectroscopy 62(7): 817-819, 2008

Thermal conductivity versus depth profiling of inhomogeneous materials using the hot disc technique. Review of Scientific Instruments 87(7): 074901, 2016

Hybrid Organic/Inorganic Materials Depth Profiling Using Low Energy Cesium Ions. Journal of the American Society for Mass Spectrometry 27(5): 908-916, 2016

Hyperspectral depth-profiling with deep Raman spectroscopy for detecting chemicals in building materials. Analyst 142(19): 3613-3619, 2017

Line-focused laser ablation for depth-profiling analysis of coated and layered materials. Applied Optics 42(30): 6057-6062, 2003

Depth profiling 137Cs and 60Co non-intrusively for a suite of industrial shielding materials and at depths beyond 50 mm. Applied Radiation and Isotopes 70(7): 1150-1153, 2012

Improving secondary ion mass spectrometry C60(n+) sputter depth profiling of challenging polymers with nitric oxide gas dosing. Analytical Chemistry 85(10): 5064-5070, 2013