Effect of patient size on mean sterile water attenuation during multiphase CT examinations



Effect of patient size on mean sterile water attenuation during multiphase CT examinations



Ajr. American Journal of Roentgenology 200(5): 1048-1053



The purpose of this study was to determine the variability of attenuation measurements in a water phantom included in the FOV during multiphase 64-MDCT. Ninety-seven consecutively registered patients undergoing multiphase kidney and liver protocol CT of the abdomen on the same 64-MDCT scanner had a sealed water bottle placed on their anterior abdomen during the examination. Region of interest (ROI) measurements of the mean attenuation (in HU) of the water bottle were made during the unenhanced, dynamic, and delayed phases of contrast enhancement. Generalized estimating equations were used to model mean attenuation in the ROI as a function of cross-sectional patient area, contrast phase, and protocol. Day of month and time of day were covariates. A phantom was created to model the patient study. The mean attenuation values in the water bottle ROIs were -13.1 HU for the kidney protocol and -9.1 HU for the liver protocol in the unenhanced phase, -11.7 HU for the kidney and -9.5 HU for the liver protocol in the dynamic phase, and -11.9 HU for the kidney and 11.0 HU for the liver protocol in the delayed phase. Kidney protocol water bottle ROI attenuation values were lower than the liver values (p = 0.04). In all phases with both protocols, the values differed from 0 HU (all p < 0.0001). Water bottle ROI attenuation decreased as patient cross-sectional area increased (-0.01 HU/cm(2), p < 0.0001). Three patients had absolute water bottle attenuation changes greater than 20 HU between phases. Day of the month (p = 0.08) and time of day (p = 0.93) were not significant factors. Phantom data supported the study findings. The mean attenuation of water decreased as patient diameter increased. Both artifactual enhancement and decrease in enhancement greater than 20 HU were found in three larger patients.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052821395

Download citation: RISBibTeXText

PMID: 23617488

DOI: 10.2214/ajr.12.9198


Related references

Re: effect of patient size on mean sterile water attenuation during multiphase CT examinations. Journal of Urology 191(2): 349-349, 2014

A patient-equivalent attenuation phantom for estimating patient exposures from automatic exposure controlled x-ray examinations of the abdomen and lumbo-sacral spine. Medical Physics 17(3): 448-453, 1990

Computing patient doses of X-ray examinations using a patient size- and sex-adjustable phantom. British Journal of Radiology 70(835): 708-718, 1997

Performance evaluation of an attenuation phantom in estimating patient exposures for automatic exposure controlled pa chest examinations. Medical Physics 9(4): 624-625, 1982

Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image. Medical Physics 39(11): 6764-6771, 2012

Multiphase program for medical examinations. Annales De L'acfas (Assoc Can Fr Av Sci) 39: 68, 1972

Lipase-catalysed synthesis of fatty acid modified chitobiose in a low-water organic solvent effect of water distribution in a multiphase reaction system. Food and bioproducts processing: transactions of the Institution of Chemical Engineers Part C 85(2): 98-103, 2007

Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinations. Medical Physics 11(6): 827-832, 1984

Determination of multiphase saturations using gamma attenuation. Eos, Transactions, American Geophysical Union 66(46): 893, 1985

MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method. Journal of Nuclear Medicine 57(4): 587-593, 2016

Particle size and loading efficiency of poly(D,L-lactic-co-glycolic acid) multiphase microspheres containing water soluble substances prepared by the hydrous and anhydrous solvent evaporation methods. Journal of Microencapsulation 16(1): 49-58, 1999

Patient-size-dependent radiation dose optimisation technique for abdominal CT examinations. Radiation Protection Dosimetry 148(2): 189-201, 2012

Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses. Medical Physics 31(3): 588-594, 2004

Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality. Medical Physics 31(3): 595-601, 2004

Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images. Medical Physics 39(11): 6772-6778, 2012