Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy



Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy



Medical Physics 35(1): 260-269



This article investigates the performance of Al2O3: C optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central-axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and 18 MV photons, and for 6, 9, 12, 16, and 20 MeV electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within +/- 1% for photon beams. Similar results were obtained for electron beams in the low-gradient region after correction for a 1.9% photon-to-electron bias. The distance-to-agreement values were of the order of 0.5-1.0 mm for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for 18 MV was (0.51 +/- 0.48)% of the response for the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at dmax within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053060481

Download citation: RISBibTeXText

PMID: 18293581

DOI: 10.1118/1.2816106


Related references

High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters. Physics in Medicine and Biology 50(23): 5619-5628, 2005

The use of optically stimulated luminescence from AL2O3:C in the dosimetry of high-energy heavy charged particle fields. Radiation Protection Dosimetry 120(1-4): 354-357, 2006

Multichannel dosemeter and Al2O3:C optically stimulated luminescence fibre sensors for use in radiation therapy: evaluation with electron beams. Radiation Protection Dosimetry 131(1): 93-99, 2008

Characterization of Al 2 O 3 optically stimulated luminescence films for 2D dosimetry using a 6 MV photon beam. Physics in Medicine and Biology 61(21): 7551-7570, 2016

Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy. Medical Physics 34(6): 2113-2118, 2007

Near-real-time radiotherapy dosimetry using optically stimulated luminescence of Al2O3:C: mathematical models and preliminary results. Medical Physics 32(4): 1094-1102, 2005

Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams. Physics in Medicine and Biology 56(18): 6065-6082, 2011

Use of optically stimulated luminescence dosimeters for in vivo dosimetry in high-dose-rate gynecological patients. BrachyTherapy 8(2): 155-0, 2009

Dosimetric characterization of optically stimulated luminescence dosimeter with therapeutic photon beams for use in clinical radiotherapy measurements. Journal of Cancer Research and Therapeutics 13(2): 304-312, 2018

Calibration of the Al2O3:C optically stimulated luminescence (OSL) signal for linear energy transfer (LET) measurements in therapeutic proton beams. Physics in Medicine and Biology 59(15): 4295-4310, 2015

Calibration of high-energy photon and electron beams for radiotherapy using AAPM 1983 and IAEA 1987 dosimetry protocols. Medical Physics 20(2 Pt 1): 293-298, 1993

Image reconstruction algorithm for optically stimulated luminescence 2D dosimetry using laser-scanned Al 2 O 3 :C and Al 2 O 3 :C,Mg films. Physics in Medicine and Biology 61(20): 7484-7506, 2017

Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams. Radiation Protection Dosimetry 120(1-4): 159-162, 2006

Analytical modeling of relative luminescence efficiency of Al2O3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles. Physics in Medicine and Biology 57(2): 437-454, 2012

Performance of Al2O3:C optically stimulated luminescence dosimeters for clinical radiation therapy applications. Australasian Physical and Engineering Sciences in Medicine 32(4): 226-232, 2010