Evaluation of Precision Xceed® meter for on-site monitoring of blood β-hydroxybutyric acid and glucose concentrations in dairy sheep



Evaluation of Precision Xceed® meter for on-site monitoring of blood β-hydroxybutyric acid and glucose concentrations in dairy sheep



Research in Veterinary Science 93(1): 435-439



The accuracy of the Precision Xceed® hand-held meter as an on-site method for measuring blood β-hydroxybutyric acid (BHBA) and glucose concentrations, for the diagnosis of pregnancy toxemia and ketosis in dry and lactating dairy sheep, was assessed. Five to eight hours after the start of the morning feed, blood was collected once from 193 clinically healthy sheep (143 dry and 50 lactating). BHBA and glucose analyses were performed with serum in the laboratory, and with whole blood with the Precision Xceed®. Overall, BHBA and glucose determinations by the two methods were not statistically different (P>0.05). Strongly significant positive correlations were found for glucose and BHBA concentrations between the Precision Xceed® and laboratory results (r=0.76, n=150, P<0.01 and r=0.99, n=193, P<0.01, respectively). The Precision Xceed® was highly sensitive (98.6%) and specific (98.2%), and had excellent test agreement for the detection of pregnancy toxemia and ketosis.

(PDF emailed within 0-6 h: $19.90)

Accession: 053061936

Download citation: RISBibTeXText

PMID: 21764413

DOI: 10.1016/j.rvsc.2011.06.019



Related references

Evaluation of the Nova Vet Meter for sheep-side monitoring of β-hydroxybutyric acid (BHBA) and description of ewe BHBA during late gestation in three flocks from the Northeastern U.S. Research in Veterinary Science 118: 491-497, 2018

Evaluation of the Abbott Precision Xceed Pro (PXP) glucose monitor for neonatal hypoglycemia. Clinical Biochemistry 44(7): 544-0, 2011

Evaluation of a new electronic handheld meter for measurement of β-hydroxybutyric acid in dairy cows. Tierarztliche Praxis. Ausgabe G, Grosstiere/Nutztiere 42(1): 5-10, 2015

Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients. Pediatric Diabetes 12(7): 649-655, 2012

Comparison of a human portable blood glucose meter, veterinary portable blood glucose meter, and automated chemistry analyzer for measurement of blood glucose concentrations in dogs. Journal of the American Veterinary Medical Association 235(11): 1309-1313, 2010

Advanced meter features improve postprandial and paired self-monitoring of blood glucose in individuals with diabetes: results of the Actions with the CONTOUR Blood Glucose Meter and Behaviors in Frequent Testers (ACT) study. Diabetes Technology & Therapeutics 14(10): 851-857, 2013

Comparison of blood serum glucose, beta hydroxybutyric acid, blood urea nitrogen and calcium concentrations in pregnant and lambed ewes. 2008

Brazilian multicenter study for the evaluation of patients' satisfaction of blood glucose self-monitoring with BGStar(®) blood glucose meter in insulinized patients with diabetes mellitus type 1 and 2. Diabetology & Metabolic Syndrome 8(1): 66-66, 2016

Multicenter evaluation of a meter for blood glucose and ketone monitoring. Diabetes 48(SUPPL 1): A62, 1999

Glucose intolerance in dairy goats with pregnancy toxemia: Lack of correlation between blood pH and beta hydroxybutyric acid values. Canadian Veterinary Journal 57(6): 635-640, 2016

2008 resource guide. Blood glucose monitoring and data management systems. Before you buy a blood glucose monitor (also known as a blood glucose meter), check with your doctor and diabetes educator. Make sure the one you choose is well suited to your particular needs. Diabetes Forecast 61(1): Rg31-2, Rg34-48, 2008

Patient perceptions of different lancing sites for self-monitoring of blood glucose: a comparison of fingertip site with palm site using the OneTouch Ultra Blood Glucose Monitoring System. Journal of Diabetes Science and Technology 4(4): 906-910, 2010

Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle. Journal of Veterinary Internal Medicine 29(6): 1718-1727, 2016

Clinical and technical evaluation of a new self-monitoring blood glucose meter: Assessment of analytical and user error. Diabetes Research & Clinical Practice 53(2): 121-128, August, 2001

Clinical evaluation and alternative site blood glucose testing of the EasyPlus mini R2N blood glucose monitoring system. Clinica Chimica Acta; International Journal of Clinical Chemistry 403(1-2): 167-172, 2009