Evaluation of a high resolving power time-of-flight mass spectrometer for drug analysis in terms of resolving power and acquisition rate



Evaluation of a high resolving power time-of-flight mass spectrometer for drug analysis in terms of resolving power and acquisition rate



Journal of the American Society for Mass Spectrometry 22(2): 379-385



Liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) is applied increasingly to various fields of small molecule analysis. The moderate resolving power (RP) of standard TOFMS instruments poses a risk of false negative results when complex biological matrices are to be analyzed. In this study, the performance of a high resolving power TOFMS instrument (maXis by Bruker Daltonik, Bremen, Germany) was evaluated for drug analysis. By flow injection analysis of critical drug mixtures, including a total of 17 compounds with nominal masses of 212-415 Da and with mass differences of 8.8-23.5 mDa, RP varied from 34,400 to 51,900 (FWHM). The effect of acquisition rate on RP, mass accuracy, and isotopic pattern fit was studied by applying 1, 2, 5, 10, and 20 Hz acquisition rates in a 16 min gradient elution LC separation. All three variables were independent of the acquisition rate, with an average mass accuracy and isotopic pattern fit factor (mSigma) of 0.33 ppm and 5.9, respectively. The average relative standard deviation of RP was 1.8%, showing high repeatability. The performance was tested further with authentic urine extracts containing a co-eluting compound pair with a nominal mass of 296 Da and an 11.2 mDa mass difference. The authentic sample components were readily resolved and correctly identified by the automated data analysis. The average RP, mass accuracy, and isotopic pattern fit were 36,600, 0.9 ppm, and 7.3 mSigma, respectively.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053063289

Download citation: RISBibTeXText

PMID: 21472597

DOI: 10.1007/s13361-010-0046-z


Related references

A high resolving power ion selector for post-source decay measurements in a reflecting time-of-flight mass spectrometer. Rapid Communications in Mass Spectrometry 12(22): 1655-1664, 1998

A high resolving power multiple reflection matrix-assisted laser desorption/ionization time-of-flight mass spectrometer. Rapid Communications in Mass Spectrometry 13(7): 620-624, 1999

Broadscale resolving power performance of a high precision uniform field ion mobility-mass spectrometer. Analyst 140(20): 6824-6833, 2015

Optimization of Resolving Power, Fragmentation, and Mass Calibration in an Orbitrap Spectrometer for Analysis of 24 Pesticide Metabolites in Urine. International Journal of Analytical Chemistry 2019: 1917369, 2019

Laser post-ionisation combined with a high resolving power orbitrap mass spectrometer for enhanced MALDI-MS imaging of lipids. Chemical Communications 53(53): 7246-7249, 2017

Fundamental studies of computed tomography (5th Report)--noise, contrast resolving power, linearity, MTF and high contrast resolving power (for eight models of scanners). Nihon Igaku Hoshasen Gakkai Zasshi. Nippon Acta Radiologica 39(3): 283-289, 1979

An infra-red prism spectrometer of high resolving power. Journal of the Optical Society of America 37(4): 296-301, 1947

A high-resolving-power x-ray spectrometer for the OMEGA EP Laser (invited). Review of Scientific Instruments 87(11): 11d504, 2016

Note: Retrofitting an analog spectrometer for high resolving power in NUV-NIR. Review of Scientific Instruments 88(11): 116101, 2017

Evaluation of the interrelationship between mass resolving power and mass error tolerances for targeted bioanalysis using liquid chromatography coupled to high-resolution mass spectrometry. Rapid Communications in Mass Spectrometry 27(2): 347-356, 2013

Resolving power of genetic analysis in terms of DNA. Heredity 10: 124, 1956

Lateral resolving power of a time-of-flight photoemission electron microscope. Applied Physics A: Materials Science and Processing 78(1): 47-51, 2004

X-ray spectrometer having 12 000 resolving power at 8 keV energy. Review of Scientific Instruments 88(10): 103107, 2017

Capitalizing Resolving Power of Density Gradient Ultracentrifugation by Freezing and Precisely Slicing Centrifuged Solution: Enabling Identification of Complex Proteins from Mitochondria by Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry. Journal of Analytical Methods in Chemistry 2016: 8183656, 2016

High mass accuracy and high mass resolving power FT-ICR secondary ion mass spectrometry for biological tissue imaging. Analytical and Bioanalytical Chemistry 405(18): 6069-6076, 2013