Feasibility of standard mechanical ventilation with low FiO2 and small endotracheal tubes during laser microlaryngeal surgery



Feasibility of standard mechanical ventilation with low FiO2 and small endotracheal tubes during laser microlaryngeal surgery



Head and Neck 32(2): 204-209



No technique can be considered as a gold standard for ventilation during direct laser CO2 laryngeal microsurgery. We evaluated the feasibility of standard ventilation with laser-safe endotracheal tubes (ETTs) and inspired O2 fraction (FiO2) = 0.21 during direct microlaryngoscopy. During total intravenous anesthesia, standard mechanical normoventilation was set with FiO2 = 0.21 and 50 mm Hg peak inspiratory pressure limit. If SpO2 was <90% for >2 minutes, FiO2 was increased to 0.3; after 4 minutes it was increased to 0.4; after another 4 minutes, positive end-expiratory pressure (PEEP) could be set at 5 cm H2O; and after another 4 minutes, surgery was stopped if SpO2 remained <90%. We studied 111 consecutive direct microlaryngoscopies on different patients. Four patients (3.6%) suffered minor intraoperative desaturation. Barotrauma was not observed, PEEP was never applied, and surgery was never stopped. Body mass index was independently predictive of the occurrence of intraoperative desaturation. Standard mechanical ventilation with FiO2 = 0.21 through laser-safe ETTs is feasible during direct microlaryngoscopy.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053221313

Download citation: RISBibTeXText

PMID: 19536859

DOI: 10.1002/hed.21168


Related references

Avoiding a wrapped endotracheal tube in laser laryngeal surgery: experiences with apneic anesthesia and metal laser-flex endotracheal tubes. Laryngoscope 100(12): 1283-1287, 1990

Intravenous anesthesia and jet ventilation for laser microlaryngeal surgery. Annals of Otology Rhinology and Laryngology 96(1 Pt 1): 29-33, 1987

Tolerance of endotracheal tubes in patients on mechanical ventilation. Medizinische Klinik Intensivmedizin und Notfallmedizin 110(1): 68-76, 2015

Anaesthesia for microlaryngeal and laser laryngeal surgery: impact of subglottic jet ventilation. Journal of Laryngology and Otology 124(6): 641-645, 2010

High frequency jet ventilation for microlaryngeal laser surgery. An improved technique. Anaesthesia 47(5): 421-424, 1992

Comparative effectiveness of standard endotracheal tubes vs. endotracheal tubes with continuous subglottic suctioning on ventilator-associated pneumonia rates. Nursing Economic$ 29(1): 15-20 37, 2011

A new device to remove obstruction from endotracheal tubes during mechanical ventilation in critically ill patients. Intensive Care Medicine 20(8): 573-576, 1994

Cuff pressure of endotracheal tubes after changes in body position in critically ill patients treated with mechanical ventilation. American Journal of Critical Care 23(1): E1-E8, 2014

Small endotracheal tubes: ventilator and intratracheal pressures during controlled ventilation. British Journal of Anaesthesia 51(4): 375-381, 1979

Endotracheal tubes for CO2 laser surgery of the larynx. Hno 32(1): 28-31, 1984

Flexible metal endotracheal tubes for ENT laser surgery. Anaesthesia and Intensive Care 15(2): 248-249, 1987

Polyvinylchloride endotracheal tubes are hazardous for CO2 laser surgery. Anesthesiology 69(5): 801-802, 1988

Evaluation of five metallic tapes for protection of endotracheal tubes during CO2 laser surgery. Anesthesia and Analgesia 68(3): 392-393, 1989

A method for determining depth of unmarked endotracheal tubes used in laser surgery. Anesthesia and Analgesia 70(3): 340, 1990

Fires of endotracheal tubes of three different materials during carbon dioxide laser surgery. Acta Anaesthesiologica Sinica 40(1): 47-51, 2002