Fragrance mix I patch test reactions in 5006 consecutive dermatitis patients tested simultaneously with TRUE Test® and Trolab® test material



Fragrance mix I patch test reactions in 5006 consecutive dermatitis patients tested simultaneously with TRUE Test® and Trolab® test material



Contact Dermatitis 63(5): 248-253



The prevalence of contact allergy to fragrance mix (FM) I varies from study to study, depending on factors such as test population, patch test material, and technique. To compare the outcome of routine patch testing with FM I TRUE Test and FM I Trolab. A total of 5006 consecutive eczema patients were patch tested with both patch test materials according to the International Contact Dermatitis Research Group. A total of 9.9% patients tested had a positive reaction to one of the FM I mixes; 4.4% to FM I TRUE Test, 9.3% to FM I Trolab, and 3.7% to both (P < 0.0001). Patients with a stronger reaction to FM I TRUE Test almost all reacted to FM I Trolab, whereas the reverse situation showed a lower association. Clinical relevance of a positive patch test reaction to FM I TRUE Test was found in 73.0%, and clinical relevance of a positive patch test reaction to FM I Trolab was found in 64.3%; 68.4% of the patients with a positive reaction to FM I TRUE Test and 54.3% with a positive reaction to FM I Trolab were positive to one or more of the eight constituents of the mix. The study is retrospective, and supplementary testing with FM components in patients with a positive reaction to the mixes was performed in a selected group of patients. Determination of clinical relevance may be biased. From this study, we cannot conclude which of the two FM I test preparations is the best for diagnostic purposes. Inclusion of both FM I tests in the baseline series to obtain a graded degree of FM I allergy for the individual patient is one option. Prospective controlled patch test studies with FM I patch test material are recommended.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053297158

Download citation: RISBibTeXText

PMID: 20946453

DOI: 10.1111/j.1600-0536.2010.01776.x


Related references

A clinical and patch test study of patients with positive patch test reactions to fragrance mix in China. Contact Dermatitis 52(4): 188-191, 2005

Course of contact allergy in consecutive eczema patients patch tested with TRUE Test panels 1 and 2 at least twice over a 12-year period. Contact Dermatitis 52(5): 242-246, 2005

Fragrance mix I: TRUE Test(®) versus pet.-based patch test. Contact Dermatitis 72(4): 256-258, 2015

Comparing patch test results of methylchloroisothiazolinone/methylisothiazolinone tested with both TRUE Test® and 100 ppm using investigator-loaded chambers. Contact Dermatitis 78(2): 159-161, 2018

A retrospective study of patch test results from 163 patients with stasis dermatitis or leg ulcers 1. discussion of the patch test results and the sensitization indices and determination of the relevancy of positive reactions. Dermatologica (Basel) 159(2): 93-100, 1979

Positive patch test reactions to nickel sulphate are not modified by neighbouring negative fragrance patch tests. A multicenter-study by the German contact dermatitis research group. Acta Dermato-Venereologica 86(4): 345-347, 2006

Preliminary studies of the TRUE test patch test system in the United States. TRUE Test Study Group. Journal of the American Academy of Dermatology 21(4 Pt 2): 841-843, 1989

CD23/Fc epsilon R11 expression in contact sensitivity reactions: a comparison between aeroallergen patch test reactions in atopic dermatitis and the nickel patch test reaction in non-atopic individuals. Clinical and Experimental Immunology 91(3): 357-361, 1993

CD23/FcR11 expression in contact sensitivity reactions: a comparison between aeroallergen patch test reactions in atopic dermatitis and the nickel patch test reaction in non-atopic individuals. Clinical & Experimental Immunology 91(3): 357-361, 1993

Positive reactions to gold sodium thiosulfate in patch test panels (TRUE Test) in Japan: A multicentre study. Contact Dermatitis 80(2): 114-117, 2019

Allergic contact dermatitis from 5-fluorouracil with positive intradermal test and doubtful patch test reactions. Contact Dermatitis 41(2): 106-107, 1999

Strip patch test vs. conventional patch test to detect type IV sensitization in patients with allergic contact dermatitis. Journal of the European Academy of Dermatology and Venereology 22(12): 1516-1517, 2008

Results of patch test using mite components in atopic dermatitis (AD) patients. 1st report. "As is patch test" using crushed mites. Nihon Hifuka Gakkai Zasshi. Japanese Journal of Dermatology 100(11): 1127-1134, 1990

The thin layer rapid use epicutaneous test (TRUE-test), a new patch test method with high accuracy. British Journal of Dermatology 112(1): 63-68, 1985

Is p-tert-butylphenol-formaldehyde resin (PTBP-FR) in TRUE Test® (Mekos test) sensitizing the tested patients?. Contact Dermatitis 73(6): 350-357, 2015