Fully automated method for simultaneous determination of total cysteine, cysteinylglycine, glutathione and homocysteine in plasma by HPLC with UV absorbance detection



Fully automated method for simultaneous determination of total cysteine, cysteinylglycine, glutathione and homocysteine in plasma by HPLC with UV absorbance detection



Journal of Chromatography. B Analytical Technologies in the Biomedical and Life Sciences 877(28): 3400-3404



A fully automated HPLC method for the simultaneous determination of total thiols in plasma samples has been developed. The method involves reductive conversion of disulfides to their reduced counterparts with the use of tris(2-carboxyethyl)phosphine. After reduction the newly formed sulfhydryl groups are reacted with 2-chloro-1-methylquinolinium tetrafluoroborate to form 2-S-quinolinium derivatives followed by deproteinization by dialysis. The reaction products are separated by reversed-phase HPLC, detected and quantified by UV absorbance detection at 355nm. The recommended HPLC procedure enables measurement of four main plasma aminothiols cysteine, cysteinylglycine, glutathione, and homocysteine with low imprecision (mean relative standard deviations within calibration range, 3.47%, 5.34%, 4.25% and 3.26%, respectively) and good sensitivity. Accuracy, expressed as the mean measured amount as percentage of added amount, was within 97.5-103.0%, 98.3-102.5%, 96.3-99.5% and 97.1-99.1%, respectively. The lower limit of quantification for all thiols was 0.5microM. The whole unattended instrument acquisition time amounts 13min.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053318052

Download citation: RISBibTeXText

PMID: 19559659

DOI: 10.1016/j.jchromb.2009.06.012


Related references

Methodology for a rapid and simultaneous determination of total cysteine, homocysteine, cysteinylglycine and glutathione in plasma by isocratic RP-HPLC. Journal of Chromatography. B Analytical Technologies in the Biomedical and Life Sciences 911: 15-20, 2012

Fully automated assay for total homocysteine, cysteine, cysteinylglycine, glutathione, cysteamine, and 2-mercaptopropionylglycine in plasma and urine. Clinical Chemistry 44(4): 825-832, 1998

Simultaneous determination of total homocysteine, cysteine, cysteinylglycine, and glutathione in human plasma by high-performance liquid chromatography: application to studies of oxidative stress. Journal of Chromatography. B Analytical Technologies in the Biomedical and Life Sciences 852(1-2): 554-561, 2007

Simultaneous determination of total plasma glutathione, homocysteine, cysteinylglycine, and methionine by high-performance liquid chromatography with electrochemical detection. Journal of Clinical Laboratory Analysis 15(3): 144-153, 2001

Simultaneous determination of total homocysteine, cysteine, glutathione, and N-acetylcysteine in brain homogenates by HPLC. Journal of Separation Science 41(16): 3241-3249, 2018

Determination of the in vivo redox status of cysteine cysteinylglycine homocysteine and glutathione in human plasma. Analytical Biochemistry 200(2): 218-229, 1992

Simultaneous determination of glutathione, cysteine, homocysteine, and cysteinylglycine in biological fluids by ion-pairing high-performance liquid chromatography coupled with precolumn derivatization. Journal of Agricultural and Food Chemistry 62(25): 5845-5852, 2014

Simultaneous determination of homocysteine, methionine and cysteine in maternal plasma after delivery by HPLC-fluorescence detection with DBD-F as a label. Biomedical Chromatography 27(6): 708-713, 2013

Thiol and disulfide forms of glutathione , cysteine , cysteinylglycine and homocysteine in human plasma. FASEB Journal 11(3): A150, 1997

Clinical usefulness of a HPLC method for simultaneous quantitation of plasma homocysteine and cysteine. Journal of the Medical Association of Thailand 91(3): 338-344, 2008

Determination of total homocysteine in plasma Comparison of a new homocysteine-immunoassay with an established HPLC-method. Netherlands Journal of Medicine 52(Suppl. ): S4, 1998

Detection of total homocysteine in plasma by automated fluorescence polarization immunoassay and HPLC. Clinical Chemistry 44(6 Part 2): A63, 1998

HPLC determination of plasma/serum homocysteine and cysteine with UV detection and solid-phase extraction on a polymeric sorbent. Biomeditsinskaia Khimiia 56(5): 609-615, 2011

Determination of plasma total homocysteine and cysteine using HPLC with fluorescence detection and an ammonium 7-fluoro-2, 1, 3-benzoxadiazole-4-sulphonate (SBD-F) derivatization protocol optimized for antioxidant concentration, derivatization reagent concentration, temperature and matrix pH. Biomedical Chromatography 10(5): 205-212, 1996

Validation and clinical application of an UHPLC method for simultaneous analysis of total homocysteine and cysteine in human plasma. Journal of Separation Science 35(24): 3427-3433, 2012