+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Functional anatomy of normal mitral valve-left ventricular complex by real-time, three-dimensional echocardiography



Functional anatomy of normal mitral valve-left ventricular complex by real-time, three-dimensional echocardiography



Journal of Heart Valve Disease 19(1): 28-34



A detailed anatomic examination of the mitral valve (MV)-left ventricular (LV) complex (annulus, leaflets, chordae, papillary muscles, and ventricular wall) is needed for the accurate assessment of functional mitral regurgitation, and for planning patient-specific valve repair. In the past, normal values for the various components of the MV-LV complex have been derived from two-dimensional echocardiography (2DE), but such measurements require unconventional image planes and allow no off-line adjustments. In addition, measurement of the LV volumes and dimensions of irregular structures (mitral annulus) is more accurate by using three-dimensional echocardiography (3DE). The study aim was to assess, quantitatively, the MV-LV complex by real-time 3DE in normal adults. The components of the MV-LV complex were measured off-line at mid-diastole (anterior MV leaflet), end-diastole and end-systole, after full volume real-time 3DE data sets had been obtained using a matrix transducer in 10 normal adults (six females, four males; mean age 25 +/- 5 years; range: 18-35 years; mean body surface area 1.8 +/- 0.2 m2). 2DE measurements were made for comparison. The 2DE measurements were systematically smaller (1-12%) than 3DE measurements, due to a foreshortening of the various components of the MV-LV complex during 2DE imaging. By 3DE imaging, MV competence in normal hearts was achieved by systolic reduction in the LV volume (58%), LV length (17%), inter-papillary muscle distance (39%), annular diameter (6% anteroposterior, 14% mediolateral), and the length of both papillary muscles (21-31%). At end-systole, the anterior MV leaflet was 20% shorter (2.5 +/- 0.3 versus 2.0 +/- 0.3 cm), due to folding at the coaptation point. These data provide normal real-time 3DE reference values for the MV-LV complex. 3DE appears superior to 2DE for accurate functional assessment of the MV-LV complex.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 053321236

Download citation: RISBibTeXText

PMID: 20329487


Related references

Left atrial reverse remodeling and functional improvement after mitral valve repair in degenerative mitral regurgitation: a real-time 3-dimensional echocardiography study. American Heart Journal 161(2): 314-321, 2011

Real-time three-dimensional transesophageal echocardiography for assessment of mitral valve functional anatomy in patients with prolapse-related regurgitation. American Journal of Cardiology 107(9): 1365-1374, 2011

Left ventricular remodeling and mitral valve surgery: prospective study with real-time 3-dimensional echocardiography and speckle tracking. Journal of Thoracic and Cardiovascular Surgery 142(3): 641-649, 2011

Three-dimensional characteristics of functional mitral regurgitation in patients with severe left ventricular dysfunction: a real-time three-dimensional colour Doppler echocardiography study. Heart 94(5): 590-596, 2008

Assessment of global and regional left ventricular volume and shape by real-time 3-dimensional echocardiography in dogs with myxomatous mitral valve disease. Journal of Veterinary Internal Medicine 25(5): 1036-1043, 2012

Chaotic echo motion in the left ventricular cavity. Visualization of ruptured chordae tendineae of the mitral valve by real-time two-dimensional echocardiography. Japanese Heart Journal 24(6): 881-890, 1983

Late diagnosis of large left ventricular pseudoaneurysm after mitral valve replacement and coronary artery bypass surgery by real-time three-dimensional echocardiography. Journal of Tehran Heart Center 7(4): 188-190, 2013

Three-Dimensional Transthoracic Echocardiography for Evaluation of Mitral Stenosis Identification of Severe Mitral Stenosis Using Real-Time Three-Dimensional Transesophageal Echocardiography During an Left Ventricular Assist Device Insertion. Anesthesia and Analgesia 123(5): 1089-1093, 2016

The evaluation of real-time 3-dimensional transthoracic echocardiography for the preoperative functional assessment of patients with mitral valve prolapse: a comparison with 2-dimensional transesophageal echocardiography. Journal of the American Society of Echocardiography 20(8): 934-940, 2007

Automated Tracking of mitral annular motion using two-dimensional echocardiography for evaluation of left ventricular function A comparison with real-time three-dimensional echocardiography. Circulation 106(19 Suppl.): II-507, 2002

Left atrial ejection fraction assessed by real-time 3-dimensional echocardiography in normal dogs and dogs with myxomatous mitral valve disease. Journal of Veterinary Internal Medicine 27(4): 884-889, 2014

Value of mitral valve tenting volume determined by real-time three-dimensional echocardiography in patients with functional mitral regurgitation. American Journal of Cardiology 98(8): 1088-1093, 2006

The value of real-time three-dimensional transesophageal echocardiography in the assessment of paravalvular leak origin following prosthetic mitral valve replacement: real-time three-dimensional echocardiography and cardiology. Turk Kardiyoloji Dernegi Arsivi 37(8): 595-596, 2009

The incremental value of regional dyssynchrony in determining functional mitral regurgitation beyond left ventricular geometry after narrow QRS anterior myocardial infarction: a real time three-dimensional echocardiography study. Echocardiography 28(6): 665-675, 2011

Quantitative measurement of mitral valve coaptation in functional mitral regurgitation: In vivo experimental study by real-time three-dimensional echocardiography. Journal of Cardiology 53(1): 94, 2009