Image noise and radiation dose using an automatic tube current modulation technique at 64-detector computed tomography: effect of off-center patient position, bowtie filter type, and scan projection radiograph



Image noise and radiation dose using an automatic tube current modulation technique at 64-detector computed tomography: effect of off-center patient position, bowtie filter type, and scan projection radiograph



Journal of Computer Assisted Tomography 33(6): 973-977



We describe the effect of the off-center position, the bowtie filter type, and the direction of scan projection radiograph on the radiation dose and image noise of 64-detector computed tomographic scans using the automatic tube current modulation technique. On anteroposterior scan projection radiographs, the tube current ratio increased, with an increase in the off-center position of the phantom irrespective of the filter size. On lateral scan projection radiographs, it remained constant with each bowtie filter type regardless of the off-center phantom position.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053683329

Download citation: RISBibTeXText

PMID: 19940670

DOI: 10.1097/rct.0b013e31819d6f6f


Related references

Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study. European Journal of Radiology 85(9): 1666-1672, 2016

Influence of Localizer and Scan Direction on the Dose-Reducing Effect of Automatic Tube Current Modulation in Computed Tomography. Radiation Protection Dosimetry 169(1-4): 136-142, 2016

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. Journal of X-Ray Science and Technology 21(4): 453-464, 2013

Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis. Acta Radiologica 52(10): 1101-1106, 2011

Quantitative assessment of image noise and streak artifact on CT image: comparison of z-axis automatic tube current modulation technique with fixed tube current technique. Computerized Medical Imaging and Graphics 33(5): 353-358, 2009

Relationships between patient size, dose and image noise under automatic tube current modulation systems. Journal of Radiological Protection 34(1): 103-123, 2014

Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system. Emergency Radiology 24(3): 233-239, 2017

Influence of maximum tube current threshold in automatic exposure control at 64-detector row CT: relationship between radiation dose reduction rate and variability of image noise. Nihon Hoshasen Gijutsu Gakkai Zasshi 65(3): 295-300, 2009

New organ-based tube current modulation method to reduce the radiation dose during computed tomography of the head: evaluation of image quality and radiation dose to the eyes in the phantom study. La Radiologia Medica 122(8): 601-608, 2017

A CONSORT-compliant prospective randomized controlled trial: radiation dose reducing in computed tomography using an additional lateral scout view combined with automatic tube current modulation: Phantom and patient study. Medicine 96(30): E7324, 2017

Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique. International Journal of Cardiovascular Imaging 30(Suppl. 2): 89-94, 2014

Use of automatic tube current modulation with a standardized noise index in young children undergoing chest computed tomography scans with 64-slice multidetector computed tomography. Acta Radiologica 50(10): 1175-1181, 2009

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997-1002, 2009

Effect of Tube Voltage (100 vs. 120 kVp) on Radiation Dose and Image Quality using Prospective Gating 320 Row Multi-detector Computed Tomography Angiography. Journal of Clinical Imaging Science 3: 62, 2013

Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography. Clinical Radiology 68(11): E570, 2013