Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique



Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique



International Journal of Cardiovascular Imaging 30(Suppl. 2): 89-94



To investigate the image quality and the minimum required radiation dose for automatic tube potential selection (ATPS) in dual-source computed tomography (DSCT) coronary computed tomography angiography (CCTA). Three hundred twenty-five consecutive patients (153 men and 172 women) undergoing CCTA were assigned to either the ATPS group (n = 172) or the control group (n = 153); the control group underwent imaging at a constant current of 120 kV. All patients were scanned in either prospectively ECG-triggered high-pitch helical mode or sequential mode. The subjective image quality score, attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), volume CT dose index (CTDIvol), and effective dose (ED) were compared between the two groups with the Student t test or Mann-Whitney U test. The subjective image quality score was not significantly different between the two groups. Imaging noise and attenuation were both significantly higher in the ATPS group than in the control group (imaging noise: 25.6 ± 7.6 versus 15.8 ± 4.0 HU, P < 0.001; attenuation: 559.6 ± 142.0 versus 412.5 ± 64.3 HU, P < 0.001). SNR and CNR were significantly lower in the ATPS group than in the control group (SNR: 23.21 ± 7.40 versus 27.71 ± 8.25, P < 0.001; CNR: 27.81 ± 8.44 versus 33.94 ± 9.69, P < 0.001). ED was significantly lower in the ATPS group than in the control group (ED: 1.25 ± 1.24 versus 2.19 ± 1.77 mSv, P < 0.001). For both groups, ED was significantly lower in the high-pitch mode than in the sequential mode. The use of ATPS for CCTA significantly reduced the radiation dose while maintaining image quality.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053683803

Download citation: RISBibTeXText

PMID: 25168405

DOI: 10.1007/s10554-014-0526-5


Related references

Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality. Journal of Thoracic Imaging 28(1): 40-48, 2013

Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography. Clinical Radiology 68(11): E570-E577, 2013

Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol. Journal of Cardiovascular Computed Tomography 6(3): 184-190, 2012

Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Investigative Radiology 54(5): 265-272, 2019

Optimization of the pediatric head computed tomography scan image quality: Reducing dose with an automatic tube potential selection in infants. Journal of Neuroradiology 43(6): 398-403, 2016

Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation. Investigative Radiology 40(8): 556-563, 2005

Scout-Based Automated Tube Potential Selection Technique (kV Assist) in Enhanced Chest Computed Tomography: Effects on Radiation Exposure and Image Quality. Journal of Computer Assisted Tomography 41(3): 442-445, 2016

Automatic tube potential selection with tube current modulation in coronary CT angiography: Can it achieve consistent image quality among various individuals?. Experimental and Therapeutic Medicine 16(1): 253-259, 2018

Coronary computed tomographic angiography using low-dose prospectively electrocardiographic triggered high-pitch spiral acquisition by dual-source computed tomography: image quality and radiation dose. Zhongguo Yi Xue Ke Xue Yuan Xue Bao. Acta Academiae Medicinae Sinicae 32(6): 597-600, 2010

Radiation dose and image quality with abdominal computed tomography with automated dose-optimized tube voltage selection. Journal of International Medical Research 42(4): 1011-1017, 2014

Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality. International Journal of Cardiovascular Imaging 29(6): 1335-1340, 2013

Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D). Plos one 10(11): E0142185, 2015

Comparison of image quality and radiation dose in computed tomography angiography of the peripheral arteries using tube voltage of 80 kV versus 100 kV. Radiologia 56(6): 541-547, 2017

Effect of Tube Voltage (100 vs. 120 kVp) on Radiation Dose and Image Quality using Prospective Gating 320 Row Multi-detector Computed Tomography Angiography. Journal of Clinical Imaging Science 3: 62, 2013

Individualized kV selection and tube current reduction in excretory phase computed tomography urography: potential for radiation dose reduction and the contribution of iterative reconstruction to image quality. Journal of Computer Assisted Tomography 37(4): 551-559, 2013