Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy



Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy



Nihon Hoshasen Gijutsu Gakkai Zasshi 67(5): 497-506



In multileaf collimator (MLC)-based intensity modulated radiation therapy (IMRT), the dose is influenced by the uncertainty of MLC driving control. In this study, we examined the influence of MLC driving control accuracy on dose evaluation (gamma analysis) by evaluating 60-day MLC driving control accuracy (stationary positioning accuracy and positioning reproducibility) once a week as well as measuring IMRT dose distribution. The MLC positioning accuracy accompanied variation over time and tended to expand by 0.1 to 0.15 mm in one week and about 1 mm in 60 days. In terms of reproducibility, errors were within 0.2 mm for more than 95%. For prostate IMRT, when MLC stationary positioning accuracy was around 1 mm, no significant difference was observed in the pass rate in gamma analysis. Therefore, the results suggest that regular maintenance by setting a permissible value determined by the MLC positioning accuracy test can be an effective indicator in the future for maintaining the safety of IMRT.

(PDF emailed within 0-6 h: $19.90)

Accession: 053720300

Download citation: RISBibTeXText

PMID: 21666373

DOI: 10.6009/jjrt.67.497



Related references

Impact of multileaf collimator leaf positioning accuracy on intensity modulation radiation therapy quality assurance ion chamber measurements. Medical Physics 32(5): 1440-1445, 2005

Impact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-MV Intensity-Modulated Radiation Therapy Treatment Plans. Journal of Medical Physics 42(3): 151-155, 2017

The effect of gantry and collimator angles on leaf limited velocity and position in dynamic multileaf collimator intensity-modulated radiation therapy. Physics in Medicine and Biology 55(11): 3101-3113, 2010

Intensity-modulated radiation therapy for mesothelioma: impact of multileaf collimator leaf width and pencil beam size on planning quality and delivery efficiency. International Journal of Radiation Oncology, Biology, Physics 62(5): 1525-1534, 2005

Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy. Radiological Physics and Technology 9(1): 121-126, 2016

Impact of the number of control points has on isodose distributions in a dynamic multileaf collimator intensity-modulated radiation therapy delivery. Medical Dosimetry 37(4): 412-416, 2013

Effect of multileaf collimator leaf width on physical dose distributions in the treatment of CNS and head and neck neoplasms with intensity modulated radiation therapy. Medical Physics 29(6): 1116-1119, 2002

Dynamic multileaf collimator performance for intensity modulated radiation therapy. International Journal of Radiation Oncology Biology Physics 48(3 Supplement): 341, 2000

Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy. Medical Physics 28(5): 752-756, 2001

A modified method of planning and delivery for dynamic multileaf collimator intensity-modulated radiation therapy. International Journal of Radiation Oncology Biology Physics 47(1): 241-245, April 1, 2000

Lateral loss and dose discrepancies of multileaf collimator segments in intensity modulated radiation therapy. Medical Physics 30(11): 2959-2968, 2003

Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator. Medical Physics 28(10): 2113-2120, 2001

Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator. Physics in Medicine and Biology 43(2): 241-260, 1998

Extra-target doses in children receiving multileaf collimator based intensity modulated radiation therapy. Pediatric Blood & Cancer 42(7): 626-630, June, 2004

Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: comparison of dynamic and segmental methods. Medical Physics 28(12): 2441-2449, 2002