In vitro and in vivo characterization of three different modes of pump operation when using a left ventricular assist device as a right ventricular assist device



In vitro and in vivo characterization of three different modes of pump operation when using a left ventricular assist device as a right ventricular assist device



Artificial Organs 38(11): 931-939



Dual rotary left ventricular assist devices (LVADs) have been used clinically to support patients with biventricular failure. However, due to the lower vascular resistance in the pulmonary circulation compared with its systemic counterpart, excessively high pulmonary flow rates are expected if the right ventricular assist device (RVAD) is operated at its design LVAD speed. Three possible approaches are available to match the LVAD to the pulmonary circulation: operating the RVAD at a lower speed than the LVAD (mode 1), operating both pumps at their design speeds (mode 2) while relying on the cardiovascular system to adapt, and operating both pumps at their design speeds while restricting the diameter of the RVAD outflow graft (mode 3). In this study, each mode was characterized using in vitro and in vivo models of biventricular heart failure supported with two VentrAssist LVADs. The effect of each mode on arterial and atrial pressures and flow rates for low, medium, and high vascular resistances and three different contractility levels were evaluated. The amount of speed/diameter adjustment required to accommodate elevated pulmonary vascular resistance (PVR) during support with mode 3 was then investigated. Mode 1 required relatively low systemic vascular resistance to achieve arterial pressures less than 100 mm Hg in vitro, resulting in flow rates greater than 6 L/min. Mode 2 resulted in left atrial pressures above 25 mm Hg, unless left heart contractility was near-normal. In vitro, mode 3 resulted in expected arterial pressures and flow rates with an RVAD outflow diameter of 6.5 mm. In contrast, all modes were achievable in vivo, primarily due to higher RVAD outflow graft resistance (more than 500 dyn·s/cm(5)), caused by longer cannula. Flow rates could be maintained during instances of elevated PVR by increasing the RVAD speed or expanding the outflow graft diameter using an externally applied variable graft occlusion device. In conclusion, suitable hemodynamics could be produced by either restricting or not restricting the right outflow graft diameter; however, the latter required an operation of the RVAD at lower than design speed. Adjustments in outflow restriction and/or RVAD speed are recommended to accommodate varying PVR.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053769742

Download citation: RISBibTeXText

PMID: 24660783

DOI: 10.1111/aor.12289


Related references

Management of three cardiogenic pulmonary edemas occurring in a patient scheduled for left ventricular assist device implantation: indicators for determining left ventricular assist device pump speed. Journal of Anesthesia 30(4): 711-715, 2016

Left Ventricular Assist Device Inflow Angle and Pump Positional Change Over Time Adverse Impact on Left Ventricular Assist Device Function. Annals of Thoracic Surgery 102(6): 1933-1940, 2016

Left Ventricular Assist Device Inflow Cannula Position May Contribute to the Development of HeartMate II Left Ventricular Assist Device Pump Thrombosis. Ochsner Journal 18(2): 131-135, 2018

Acoustic Characterization of Axial Flow Left Ventricular Assist Device Operation In Vitro and In Vivo. Asaio Journal 62(1): 46-55, 2016

Liberal Right Ventricular Assist Device Extracorporeal Membrane Oxygenation Support for Right Ventricular Failure after Implantable Left Ventricular Assist Device Placement. Asaio Journal 64(6): 741-747, 2017

Results of Unplanned Right Ventricular Assist Device for Severe Right Ventricular Failure after Continuous Flow Left Ventricular Assist Device Insertion. The Journal of Heart and Lung Transplantation 37(4): S370-S371, 2018

Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable left ventricular assist device placement. European Journal of Cardio-Thoracic Surgery 49(1): 73-77, 2016

Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device; Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure; Increase in Left Ventricular Assist Device Thrombosis. New England Journal of Medicine 379(7): 697-697, 2018

Use of the percutaneous left ventricular assist device in patients with severe refractory cardiogenic shock as a bridge to long-term left ventricular assist device implantation. Journal of Heart and Lung Transplantation 27(1): 106-111, 2008

Extending the perspective on left ventricular assist device pump thrombosis to left ventricular assist device system thrombosis. Journal of Thoracic and Cardiovascular Surgery 155(1): E37-E38, 2018

Feasibility of cell transplantation with a left ventricular assist device to improve the success rate of left ventricular assist device removal: the first experiment. Interactive Cardiovascular and Thoracic Surgery 12(1): 10-14, 2011

Contemporary outcome of unplanned right ventricular assist device for severe right heart failure after continuous-flow left ventricular assist device insertion. Interactive Cardiovascular and Thoracic Surgery 24(6): 828-834, 2017

Ablation of an electrical storm in a patient with giant cell myocarditis using continuous flow left ventricular assist device and percutaneous right ventricular assist device. International Journal of Cardiology 209: 84-86, 2016

Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion. Journal of Heart and Lung Transplantation 33(2): 141-148, 2014

A Novel Toroidal-Flow Left Ventricular Assist Device Minimizes Blood Trauma: Implications of Improved Ventricular Assist Device Hemocompatibility. Annals of Thoracic Surgery 107(6): 1761-1767, 2019