Influence of adhesive point dimension and splint type on splint rigidity--evaluation by the dynamic Periotest method



Influence of adhesive point dimension and splint type on splint rigidity--evaluation by the dynamic Periotest method



Dental Traumatology 29(3): 203-211



To evaluate the influence of adhesive point dimension and splint type on the rigidity of wire-composite splints in vitro. A custom-made artificial model was used. The two central incisors served as injured teeth (degrees of loosening III and II) and the two lateral incisors as non-injured teeth (physiological mobility). Horizontal and vertical tooth mobilities were investigated before and after splinting with the Periotest(®) method; the percent change was taken as the relative splint effect. Teeth were splinted with three types of wire-composite splints: Dentaflex (0.45 mm), Strengtheners (0.8 × 1.8 mm), and Dentaflex completely covered with composite. Four adhesive point dimensions (2, 3, 4, and 5 mm) were evaluated. Normal distribution was tested with the Kolmogorov-Smirnov test. Differences were evaluated with the anova and post hoc tests for pair-wise comparisons. Significance level was set at 0.05. The adhesive point dimension did not influence splint rigidity, in general ( P  = 0.288). Significant effects were found in non-injured teeth with the Dentaflex ( P  < 0.001) and in injured teeth with the Strengtheners ( P  < 0.001). The Strengtheners splint rigidity increased significantly with increasing adhesive point dimensions. The three splints showed significantly different effects at 5-mm adhesive point dimension ( P  < 0.001). Splint rigidity for injured teeth was influenced by adhesive point dimension only when splinting with Strengtheners. We recommend adapting splint rigidity by selecting different wires and reducing the adhesive point dimension to a minimum. Dentaflex can be used for flexible splinting, Strengtheners, and composite covered Dentaflex for rigid splinting.

(PDF emailed within 0-6 h: $19.90)

Accession: 053837579

Download citation: RISBibTeXText

PMID: 22816496

DOI: 10.1111/j.1600-9657.2012.01164.x



Related references

Influence of adhesive point dimension and splint type on splint rigidity – Evaluation by the dynamic Periotest method. Dental Traumatology aop(aop), 2012

Influence of abutment tooth position and adhesive point dimension on the rigidity of a dental trauma wire-composite splint. Dental Traumatology 32(3): 225-230, 2018

Influence of wire extension and type on splint rigidity – evaluation by a dynamic and a static measuring method. Dental Traumatology 27(6): 422-431, 2011

Influence of wire extension and type on splint rigidity--evaluation by a dynamic and a static measuring method. Dental Traumatology 27(6): 422-431, 2012

In vitro splint rigidity evaluation – comparison of a dynamic and a static measuring method. Dental Traumatology 27(6): 414-421, 2011

In vitro splint rigidity evaluation--comparison of a dynamic and a static measuring method. Dental Traumatology 27(6): 414-421, 2012

Splinting of Colles' fracture. Dynamic splint in supination compared with conventional dorsal plaster splint. Ugeskrift for Laeger 147(20): 1619-1622, 1985

Apparatus having a ureter splint and a guide connectable to the splint via a screw connection, and having an auxiliary splint. Official Gazette of the United States Patent & Trademark Office Patents 1215(1): 442-443, Oct 6, 1998

Use of the Thomas splint and cast combination, walker splint, and spica bandage with an over the shoulder splint for the treatment of fractures of the upper limbs in cattle. Veterinary Clinics of North America. Food Animal Practice 30(1): 77-90, V-Vi, 2014

A Method To Incorporate A Fixed Horizontal Pin Splint With A Veneer Crown As A Single Splint. Dental Digest 71: 250-3 Passim, 1965

Influence of the relaxation splint and stabilization splint on the EMG parameters of the masticatory muscles. Shanghai Kou Qiang Yi Xue 11(1): 22-24, 2004

A method for converting a mallet finger splint into a boutonnière splint. Journal of Hand Therapy 8(3): 214-214, 1995

Treatment effect on signs and symptoms of temporomandibular disorders--comparison between stabilisation splint and a new type of splint (NTI). A pilot study. Swedish Dental Journal 28(1): 11-20, 2004

Development of new artificial models for splint rigidity evaluation. Dental Traumatology 27(5): 356-367, 2012

A comparative study of the "Levame" type extension splint and the "Low Profile" type extension splint: impact on therapeutic indications. Annales de Chirurgie de la Main et du Membre Superieur 13(5): 308-316, 1994