Initial acute in vivo performance of the Cleveland Clinic PediPump left ventricular assist device



Initial acute in vivo performance of the Cleveland Clinic PediPump left ventricular assist device



Asaio Journal 53(6): 766-770



The PediPump is a small ventricular assist device (VAD) with a hydraulic output range designed to support children from newborns to adolescents. The present report describes our initial evaluation of the PediPump as a left VAD in an acute sheep model. The PediPump was implanted in two sheep (50.8 and 62.7 kg). Pump speed was adjusted to achieve a flow of 2 L/min with the naturally occurring preload and afterload conditions to evaluate pump performance under a steady hemodynamic state for 4 hours. Upon completion, pump performance was evaluated under various blood pressure and heart rate conditions. During steady-state evaluations, the ascending aortic flow and pump speed varied slightly depending on systemic arterial pressure variations. During the hemodynamic manipulation studies, flows ranged between 0.5 and 3.2 L/min with pump speeds of 5,200-16,200 rpm and motor current of 0.06-0.75 A. The PediPump demonstrated good initial hemodynamic performance for use as an implantable left VAD. However, some depositions were detected at the time of explanation, mainly at the rear of the pump. We are continuing with further acute studies to evaluate pump performance in anticipation of beginning chronic studies to evaluate long-term biocompatibility.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 053872859

Download citation: RISBibTeXText

PMID: 18043163

DOI: 10.1097/mat.0b013e3181569c1a


Related references

Short-term in vivo performance of the Cleveland clinic PediPump left ventricular assist device. Artificial Organs 38(5): 374-382, 2014

Initial experience of conversion of Toyobo paracorporeal left ventricular assist device to DuraHeart left ventricular assist device. Circulation Journal 76(2): 372-376, 2012

Initial In Vivo Evaluation of a Novel Left Ventricular Assist Device. Biomed Research International 2015: 148579, 2015

Implantable continuous-flow right ventricular assist device: lessons learned in the development of a cleveland clinic device. Annals of Thoracic Surgery 93(5): 1746-1752, 2012

External left ventricular performance in the calf during acute ischemia and with abdominal left ventricular assist device support. Circulation Suppl 50(4-3): III167, 1974

In vitro and in vivo characterization of three different modes of pump operation when using a left ventricular assist device as a right ventricular assist device. Artificial Organs 38(11): 931-939, 2014

The PediPump: a new ventricular assist device for children. Artificial Organs 29(7): 527-530, 2005

The pedipump: development status of a new pediatric ventricular assist device. Asaio Journal 51(5): 536-539, 2005

Chronic evaluation of the Cleveland Clinic CorAide left ventricular assist system in calves. Artificial Organs 26(6): 529-533, 2002

The PediPump: a versatile, implantable pediatric ventricular assist device--update IV. Artificial Organs 33(11): 1005-1008, 2009

The PediPump: development status of a new pediatric ventricular assist device: update II. Asaio Journal 52(5): 581-587, 2006

Intra-operative fitting study of the PediPump ventricular assist device. Journal of Heart and Lung Transplantation 31(1): 109-110, 2012

The PediPump: a versatile, implantable pediatric ventricular assist device-update III. Asaio Journal 53(6): 730-733, 2007

Initial experience with the Impella left ventricular assist device for postcardiotomy cardiogenic shock and unprotected left coronary artery angioplasty in patients with a low left ventricular ejection fraction. Revista Espanola de Cardiologia 60(9): 984-987, 2007

Management of three cardiogenic pulmonary edemas occurring in a patient scheduled for left ventricular assist device implantation: indicators for determining left ventricular assist device pump speed. Journal of Anesthesia 30(4): 711-715, 2016