+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Intensity transmitted by a Fabry-Perot etalon with another internal Fabry-Perot interferometer



Intensity transmitted by a Fabry-Perot etalon with another internal Fabry-Perot interferometer



Applied Optics 20(12): 2117-2120



The intensity transmitted by a device made up of a F.P. etalon that contains another internal tunable F.P. has been studied. The theoretical predictions about the wavelengths of the intensity transmission maxima of the device are derived as functions of the optical path length of the internal F.P. An experimental check of the theoretical predictions is also presented.

(PDF emailed within 0-6 h: $19.90)

Accession: 053899076

Download citation: RISBibTeXText

PMID: 20332896

DOI: 10.1364/AO.20.002117


Related references

Laser-bandwidth-induced fluctuations in the intensity transmitted by a Fabry-Pérot interferometer. Physical Review. A, Atomic, Molecular, and Optical Physics 44(5): 3222-3228, 1991

Full-field vibrometry using a Fabry-Perot étalon interferometer. Applied Optics 31(34): 7301-7308, 1992

Stable and rugged etalon for the Dynamics Explorer Fabry-Perot interferometer. 2: Performance. Applied Optics 21(21): 3903-3912, 1982

Stable and rugged etalon for the Dynamics Explorer Fabry-Perot interferometer. 1: Design and construction. Applied Optics 21(21): 3896-3902, 1982

Global Tropospheric and Total Ozone Monitoring with a Double-Etalon Fabry-Perot Interferometer. II. Feasibility Analysis. Applied Optics 37(21): 4732-4743, 2008

Global tropospheric and total ozone monitoring with a double-etalon fabry-perot interferometer. I. Instrument concept. Applied Optics 37(21): 4721-4731, 2008

Transmitted amplitude by a Fabry-Perot interferometer with random surface defects. Applied Optics 24(3): 315-316, 1985

Exact evaluation of the transmitted amplitude for a Fabry-Perot interferometer with surface defects. Applied Optics 25(10): 1646, 1986

Transmitted characteristics for a Gaussian beam passing through a misaligned Fabry-Perot interferometer. Optik - International Journal for Light and Electron Optics 114(12): 521-524, 2003

A technique for recovering Doppler line profiles from fabry-perot interferometer fringes of very low intensity. Applied Optics 10(1): 193-200, 1971

Influence of intensity loss in the cavity of a folded Fabry-Perot interferometer on interferometric signals. Review of Scientific Instruments 82(6): 063103, 2011

Gravity-adjusted fabry-perot etalon. Applied Optics 8(11): 2345-2346, 1969

Solid, 3-mirror Fabry-Perot etalon. Applied Optics 56(10): 2636-2640, 2017

Rapid scanning with the fabry-perot etalon. Applied Optics 7(11): 2166-2170, 1968

Cryogenic far-infrared Fabry-Perot étalon. Applied Optics 30(31): 4493-4495, 1991