Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions)



Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions)



Jacc. Cardiovascular Interventions 2(12): 1208-1218



The aim of this study was to assess, after 2 years of follow-up, the safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent (ZES) compared with a paclitaxel-eluting stent (PES) in patients with native coronary lesions. Early drug-eluting stents were associated with a small but significant incidence of very late stent thrombosis (VLST), occurring >1 year after the index procedure. The ZES has shown encouraging results in clinical trials. The ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions), a randomized (1:1), single-blind, controlled trial (n = 1,548) compared ZES versus PES in patients with single de novo coronary lesions. Two-year follow-up was obtained in 96.0% of ZES and 95.4% of PES patients. The primary end point was target vessel failure (TVF), and safety end points included Academic Research Consortium-defined stent thrombosis. Economic end points analyzed included quality-adjusted survival, medical costs, and relative cost-effectiveness of ZES and PES. The TVF at 2 years was similar in ZES and PES patients (11.1% vs. 13.1%, p = 0.232). There were fewer myocardial infarctions (MIs) in ZES patients (p = 0.022), due to fewer periprocedural non-Q-wave MIs and fewer late MIs between 1 and 2 years. Late MIs were associated with increased VLST (PES: 6 vs. ZES: 1; p = 0.069). Target lesion revascularization was similar comparing ZES with PES (5.9% vs. 4.6%; p = 0.295), especially in patients without planned angiographic follow-up (5.2% vs. 4.9%; p = 0.896). The cost-effectiveness of ZES and PES was similar. After 2 years of follow-up, ZES demonstrated efficacy and cost-effectiveness comparable to PES, with fewer MIs and a trend toward less VLST. (The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions; NCT00217269).

(PDF emailed within 0-6 h: $19.90)

Accession: 054085614

Download citation: RISBibTeXText

PMID: 20129547

DOI: 10.1016/j.jcin.2009.10.008



Related references

Long-term clinical and economic analysis of the Endeavor zotarolimus-eluting stent versus the cypher sirolimus-eluting stent: 3-year results from the ENDEAVOR III trial (Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions). Jacc. Cardiovascular Interventions 2(12): 1199-1207, 2010

Late-term clinical outcomes with zotarolimus- and sirolimus-eluting stents. 5-year follow-up of the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions). Jacc. Cardiovascular Interventions 4(5): 543-550, 2011

Long-term clinical and economic analysis of the Endeavor drug-eluting stent versus the Driver bare-metal stent: 4-year results from the ENDEAVOR II trial (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions). Jacc. Cardiovascular Interventions 2(12): 1178-1187, 2010

A randomized comparison of the Endeavor zotarolimus-eluting stent versus the TAXUS paclitaxel-eluting stent in de novo native coronary lesions 12-month outcomes from the ENDEAVOR IV trial. Journal of the American College of Cardiology 55(6): 543-554, 2010

Late-Term Clinical Outcomes With Zotarolimus- and Sirolimus-Eluting Stents 5-Year Follow-Up of the ENDEAVOR III A Randomized Controlled Trial of the Medtronic Endeavor Drug ABT-578 Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coro. 2011

Late-Term Clinical Outcomes With Zotarolimus- and Sirolimus-Eluting Stents5-Year Follow-Up of the ENDEAVOR III A Randomized Controlled Trial of the Medtronic Endeavor Drug ABT-578 Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Corona. 2011

Improved late clinical safety with zotarolimus-eluting stents compared with paclitaxel-eluting stents in patients with de novo coronary lesions: 3-year follow-up from the ENDEAVOR IV (Randomized Comparison of Zotarolimus- and Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease) trial. Jacc. Cardiovascular Interventions 3(10): 1043-1050, 2011

Long-term follow-up of the randomised controlled trial to evaluate the safety and efficacy of the zotarolimus-eluting driver coronary stent in de novo native coronary artery lesions: five year outcomes in the ENDEAVOR II study. Eurointervention 6(5): 562-567, 2011

Two-year follow-up of the NEVO ResElution-I(NEVO RES-I) trial: a randomised, multicentre comparison of the NEVO sirolimus-eluting coronary stent with the TAXUS Liberté paclitaxel-eluting stent in de novo native coronary artery lesions. Eurointervention 9(6): 721-729, 2016

Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: two-year clinical follow-up from the Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions (SPIRIT) III trial. Circulation 119(5): 680-686, 2009

5-year results of a randomized comparison of XIENCE V everolimus-eluting and TAXUS paclitaxel-eluting stents: final results from the SPIRIT III trial (clinical evaluation of the XIENCE V everolimus eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions). Jacc. Cardiovascular Interventions 6(12): 1263-1266, 2014

Six-month results of the NEVO Res-Elution I (NEVO RES-I) trial: a randomized, multicenter comparison of the NEVO sirolimus-eluting coronary stent with the TAXUS Liberté paclitaxel-eluting stent in de novo native coronary artery lesions. Circulation. Cardiovascular Interventions 3(6): 556-564, 2011

The clinical evaluation of the Endeavor zotarolimus-eluting coronary stent in Japanese patients with de novo native coronary artery lesions: primary results and 3-year follow-up of the Endeavor Japan study. Cardiovascular Revascularization Medicine 12(5): 273-279, 2012

A randomized trial to confirm the safety and efficacy of the medtronic zotarolimus eluting coronary stent in de novo native coronary artery lesions. Herz 32(3): 251, 2007

Comparison of zotarolimus-eluting stents with sirolimus- and paclitaxel-eluting stents for coronary revascularization: the ZEST (comparison of the efficacy and safety of zotarolimus-eluting stent with sirolimus-eluting and paclitaxel-eluting stent for coronary lesions) randomized trial. Journal of the American College of Cardiology 56(15): 1187-1195, 2010