Lead thrombi associated with externalized cables on Riata ICD leads: a case series



Lead thrombi associated with externalized cables on Riata ICD leads: a case series



Journal of Cardiovascular Electrophysiology 24(9): 1047-1050



St. Jude Riata family ICD leads are subject to an FDA class I recall due to insulation failure, cable extrusions, and a high rate of electrical failures. We present multiple cases of large intravascular thrombus formation adherent to externalized conductor cables on Riata leads. Our observations highlight a previously unknown risk of large or calcified thrombus formation involving externalized conductors. We suggest that these leads should be screened for thrombi prior to potential lead extraction to determine the safest approach. Serial echocardiography may help detect progressive thrombus formation. The role of systemic anticoagulation for prevention or treatment of these thrombi remains unclear.

(PDF emailed within 0-6 h: $19.90)

Accession: 054091633

Download citation: RISBibTeXText

PMID: 23577693

DOI: 10.1111/jce.12134


Related references

Increasing lead burden correlates with externalized cables during systematic fluoroscopic screening of Riata leads. Journal of Interventional Cardiac Electrophysiology 37(1): 63-68, 2014

Prevalence of externalized conductors in Riata and Riata ST silicone leads: results from the prospective, multicenter Riata Lead Evaluation Study. Heart Rhythm 10(12): 1778-1782, 2014

High prevalence of insulation failure with externalized cables in St. Jude Medical Riata family ICD leads: fluoroscopic grading scale and correlation to extracted leads. Heart Rhythm 9(8): 1218-1224, 2013

Externalized Conductor Cables in QuickSite Left Ventricular Pacing Lead and Riata Right Ventricular Lead in a Single Patient: A Common Problem With Silicone Insulation. Cardiology Research 3(5): 230-231, 2012

A case of in vivo thrombogenicity of an externalized Riata ST lead. Europace 15(3): 428, 2013

Could Externalized St. Jude Medical Riata® Lead Be a Culture Medium of a Polymicrobial Endocarditis? A Clinical Case. Case Reports in Cardiology 2017: 8967234, 2017

Longitudinal follow-up of externalized Riata leads. American Journal of Cardiology 112(10): 1616-1618, 2014

Labelled leucocyte scintigraphy in an infected externalized Riata lead. Europace 16(10): 1442, 2015

Contribution of ethylenetetrafluoroethylene (ETFE) insulation to the electrical performance of Riata® silicone leads having externalized conductors. Journal of Interventional Cardiac Electrophysiology 37(2): 141-145, 2014

Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee. Circulation. Arrhythmia and Electrophysiology 5(6): 1059-1063, 2013

Failure of fluoroscopy to detect "inside-out" insulation failure and externalized conductors in a Riata ICD lead. Heart Rhythm 10(12): 1827-1828, 2014

Repetitive inappropriate implantable cardioverter-defibrillator shocks due to insulation failure with externalized conductor cables of a Biotronik Linox SD ICD lead. Europace 18(5): 686, 2017

Independent multicenter study of Riata and Riata ST implantable cardioverter-defibrillator leads. Heart Rhythm 10(3): 361-365, 2013

Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads. Heart Rhythm 9(8): 1227-1235, 2013

Long-term Electrical Survival Analysis of Riata and Riata ST Silicone Leads—National VA Experience. 2012