+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Localization events-based sample drift correction for localization microscopy with redundant cross-correlation algorithm



Localization events-based sample drift correction for localization microscopy with redundant cross-correlation algorithm



Optics Express 22(13): 15982-15991



Highly accurate sample drift correction is essential in super-resolution localization microscopy to guarantee a high spatial resolution, especially when the technique is used to visualize small cell organelle. Here we present a localization events-based drift correction method using a redundant cross-correlation algorithm originally developed to correct beam-induced motion in cryo-electron microscopy. With simulated, synthesized as well as experimental data, we have demonstrated its superior precision compared to previously published localization events-based drift correction methods. The major advantage of this method is the robustness when the number of localization events is low, either because a short correction time step is required or because the imaged structure is small and sparse. This method has allowed us to improve the effective resolution when imaging Golgi apparatus in mammalian cells.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 054153582

Download citation: RISBibTeXText

PMID: 24977854


Related references

Sample drift correction in 3D fluorescence photoactivation localization microscopy. Optics Express 19(16): 15009-15019, 2011

Phasor based single-molecule localization microscopy in 3D (pSMLM-3D): An algorithm for MHz localization rates using standard CPUs. Journal of Chemical Physics 148(12): 123311, 2018

Optimal Drift Correction for Superresolution Localization Microscopy with Bayesian Inference. Biophysical Journal 109(9): 1772-1780, 2015

Real-time adaptive drift correction for super-resolution localization microscopy. Optics Express 23(18): 23887-23898, 2015

Bleed-through correction for rendering and correlation analysis in multi-colour localization microscopy. Journal of Optics 15(9):, 2013

Temporal superresolution based on a localization microscopy algorithm. Applied Optics 56(9): D24-D28, 2017

Redundant RNA recognition events in bicoid mRNA localization. Rna 3(12): 1413-1420, 1997

Signal drift of oxygen optical sensors. Part II: Smart drift correction algorithm and its experimental check with a light intensity detection based sensor. Sensors and Actuators B: Chemical 181: 949-954, 2013

Correlation analysis framework for localization-based superresolution microscopy. Proceedings of the National Academy of Sciences of the United States of America 115(13): 3219-3224, 2018

TestSTORM: Simulator for optimizing sample labeling and image acquisition in localization based super-resolution microscopy. Biomedical Optics Express 5(3): 778-787, 2014

Feedback based simultaneous correction of imaging artifacts due to geometrical and mechanical cross-talk and tip-sample stick in atomic force microscopy. Review of Scientific Instruments 78(10): 103706, 2007

Passive localization in the deep ocean based on cross-correlation function matching. Journal of the Acoustical Society of America 139(6): El196, 2016

NLScore: a novel quantitative algorithm based on 3 dimensional structural determinants to predict the probability of nuclear localization in proteins containing classical nuclear localization signals. Journal of Molecular Modeling 23(9): 258, 2017

Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction. Magnetic Resonance in Medicine 70(4): 895-904, 2013