Longitudinal evaluation of optic disc measurement variability with optical coherence tomography and confocal scanning laser ophthalmoscopy



Longitudinal evaluation of optic disc measurement variability with optical coherence tomography and confocal scanning laser ophthalmoscopy



Journal of Glaucoma 18(2): 101-106



To evaluate and compare the longitudinal variability of optical coherence tomography (OCT) and confocal scanning laser ophthalmoscopy (CSLO) optic disc measurements. A total of 25 normal and 50 glaucomatous eyes from 75 subjects were included in the analysis. The optic disc was measured by OCT and CSLO. Three separate measurements collected over an average period of 8.5+/-0.9 months were used to evaluate reproducibility. Univariate and multivariate regression analyses were performed to evaluate the associations between age, refraction, diagnosis (glaucoma or normal), visual field mean deviation, optic disc area, signal strength variance (OCT), optic disc area variance (OCT), image quality SD (CSLO), reference height variance (CSLO), and rim area variability. The intraclass correlation coefficient of optic disc measurements (except for optic disc area) ranged between 0.86 and 0.95 for OCT and between 0.89 and 0.96 for CSLO. The intraclass correlation coefficient for rim area measurement was significantly higher in CSLO (0.95) than that of OCT (0.86, P<0.001). After adjustment for other predictors, optic disc area variance and reference height variance were the most important factors responsible for rim area variability in OCT and CSLO, respectively. Although both OCT and CSLO have relatively low variability for optic disc measurements, CSLO demonstrates higher measurement reproducibility for rim area compared with OCT. Variations of disc area in OCT and reference height in CSLO constituted a significant proportion of the rim area variability during longitudinal assessment.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 054175317

Download citation: RISBibTeXText

PMID: 19225344

DOI: 10.1097/ijg.0b013e318179f879


Related references

Evaluation of the influence of tilt of optic disc on the measurement of optic disc variables obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy. Journal of Glaucoma 14(3): 210-214, 2005

Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy. Investigative Ophthalmology and Visual Science 48(7): 3178-3183, 2007

Correlations between digital planimetry and optical coherence tomography, confocal scanning laser ophthalmoscopy in assessment of optic disc parameters. Medicina 48(3): 150-158, 2012

Comparison of optic disc parameters using spectral domain cirrus high-definition optical coherence tomography and confocal scanning laser ophthalmoscopy in normal eyes. Acta Ophthalmologica 90(3): E225-E229, 2012

Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy. American Journal of Ophthalmology 135(4): 504-512, 2003

Assessment of the optic disc morphology using spectral-domain optical coherence tomography and scanning laser ophthalmoscopy. Biomed Research International 2014: 275654, 2015

Comparing optic nerve head analysis between confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography. Current Eye Research 39(10): 1026-1032, 2015

Comparison of scanning laser ophthalmoscopy and high-definition optical coherence tomography measurements of optic disc parameters. British Journal of Ophthalmology 96(4): 576-580, 2012

Comparison of a novel confocal scanning laser ophthalmoscopy algorithm with optical coherence tomography in measurement of macular thickness and volume. Retina 29(9): 1328-1334, 2010

Association of retinal nerve fibre layer thickness measured by confocal scanning laser ophthalmoscopy and optical coherence tomography with disc size and axial length. British Journal of Ophthalmology 92(2): 186-190, 2008

Longitudinal analysis of reticular drusen associated with age-related macular degeneration using combined confocal scanning laser ophthalmoscopy and spectral-domain optical coherence tomography imaging. Ophthalmologica. Journal International d'Ophtalmologie. International Journal of Ophthalmology. Zeitschrift für Augenheilkunde 233(1): 35-42, 2015

Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry. Investigative Ophthalmology and Visual Science 47(7): 2889-2895, 2006

Clinical evaluation of simultaneous confocal scanning laser ophthalmoscopy imaging combined with high-resolution, spectral-domain optical coherence tomography. Acta Ophthalmologica 88(8): 842-849, 2011

Optical coherence tomography, scanning laser polarimetry and confocal scanning laser ophthalmoscopy in retinal nerve fiber layer measurements of glaucoma patients. Open Ophthalmology Journal 9: 41-48, 2015

Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage. Graefe's Archive for Clinical and Experimental Ophthalmology 244(1): 58-68, 2005