+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

MALDI-TOF serum profiling using semiautomated serum peptide capture with magnetic reversed phase (C18) beads



MALDI-TOF serum profiling using semiautomated serum peptide capture with magnetic reversed phase (C18) beads



Methods in Molecular Biology 790: 3-16



Mass spectrometry can be used to generate diagnostic peptide peak profiles "signatures" of serum samples. Peak profiles can be used to compare different sera and correlate samples (i.e., patient groups) with clinical data to assist in diagnosis, monitoring, and/or prediction. We describe the semiautomated capture of serum peptides/small proteins with magnetic beads that harbor C18 alkyl chains, the deposition of captured material on a target plate for MALDI-TOF mass spectrometry, as well as, general guidelines for data acquisition. We also include, in a separate note, a short manual version of the capture procedure. Overall, the serum sample processing protocol, reported here, is reproducible and robust. In conjunction with MALDI-TOF mass spectrometry, this protocol allows for the profiling of several hundreds of serum peptides.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 054204613

Download citation: RISBibTeXText

PMID: 21948402


Related references

Automated serum peptide profiling using novel magnetic C18 beads off-line coupled to MALDI-TOF-MS. Proteomics. Clinical Applications 1(6): 598-604, 2007

Detection of Leishmania donovani infection using magnetic beads-based serum peptide profiling by MALDI-TOF MS in mice model. Parasitology Research 110(3): 1287-1290, 2012

Serum peptide profiling using MALDI mass spectrometry: avoiding the pitfalls of coated magnetic beads using well-established ZipTip technology. Proteomics 7(Suppl. 1): 77-89, 2007

Proteomic Profiling of Invasive Ductal Carcinoma (IDC) using Magnetic Beads-based Serum Fractionation and MALDI-TOF MS. Journal of Clinical Laboratory Analysis 29(4): 321-327, 2015

Detection of murine toxoplasmosis using magnetic bead-based serum peptide profiling by MALDI-TOF MS. Vector Borne and Zoonotic Diseases 12(6): 462-466, 2012

Serum peptide profiling by magnetic particle-assisted, automated sample processing and MALDI-TOF mass spectrometry. Analytical Chemistry 76(6): 1560-1570, 2004

A new approach to profile ovarian cancer serum using functionalized magnetic beads, AnchorChipTM technology, MALDI-TOF MS, MALDI-TOF/TOF MS and bioinformatics. Molecular and Cellular Proteomics 2(7 Suppl.): S31, 2003

Impact of experimental and demographic variables in serum peptide profiling based on magnetic bead and MALDI-TOF mass spectrometry. Clinica Chimica Acta; International Journal of Clinical Chemistry 412(1-2): 112-119, 2011

Early diagnosis of Irkut virus infection using magnetic bead-based serum peptide profiling by MALDI-TOF MS in a mouse model. International Journal of Molecular Sciences 15(4): 5193-5198, 2014

Quality control based on isotopic distributions for high-throughput MALDI-TOF and MALDI-FTICR serum peptide profiling. Journal of the American Society for Mass Spectrometry 21(9): 1515-1525, 2010

Endogeneous peptide profiling of cerebrospinal fluid by MALDI-TOF mass spectrometry: Optimization of magnetic bead-based peptide capture and analysis of preanalytical variables. Proteomics. Clinical Applications 1(11): 1385-1392, 2007

Proteomic expression profiling and identification of serum proteins using immobilized trypsin beads with MALDI-TOF/TOF. Journal of Proteome Research 8(9): 4182-4192, 2009

Identification of serum biomarkers for ovarian cancer using MALDI-TOF-MS combined with magnetic beads. International Journal of Clinical Oncology 17(2): 89-95, 2012

Discovery of serum protein biomarkers in rheumatoid arthritis using MALDI-TOF-MS combined with magnetic beads. Clinical and Experimental Medicine 12(3): 145-151, 2012

A novel and rapid approach to protein expression profiling of cerebrospinal fluid from medulloblastoma patients using functionalized magnetic beads, AnchorChipTM technology, MALDI - TOf and MALDI - TOF/TOF mass spectrometry. Society for Neuroscience Abstract Viewer and Itinerary Planner : Abstract No 751 3, 2003