+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Magnetization transfer proportion: a simplified measure of dose response for polymer gel dosimetry



Magnetization transfer proportion: a simplified measure of dose response for polymer gel dosimetry



Physics in Medicine and Biology 53(24): 7107-7124



The response to radiation of polymer gel dosimeters has most often been described by measuring the nuclear magnetic resonance transverse relaxation rate as a function of dose. This approach is highly dependent upon the choice of experimental parameters, such as the echo spacing time for Carr-Purcell-Meiboom-Gill-type pulse sequences, and is difficult to optimize in imaging applications where a range of doses are applied to a single gel, as is typical for practical uses of polymer gel dosimetry. Moreover, errors in computing dose can arise when there are substantial variations in the radiofrequency (B1) field or resonant frequency, as may occur for large samples. Here we consider the advantages of using magnetization transfer imaging as an alternative approach and propose the use of a simplified quantity, the magnetization transfer proportion (MTP), to assess doses. This measure can be estimated through two simple acquisitions and is more robust in the presence of some sources of system imperfections. It also has a dependence upon experimental parameters that is independent of dose, allowing simultaneous optimization at all dose levels. The MTP is shown to be less susceptible to B1 errors than are CPMG measurements of R2. The dose response can be optimized through appropriate choices of the power and offset frequency of the pulses used in magnetization transfer imaging.

(PDF emailed within 0-6 h: $19.90)

Accession: 054223315

Download citation: RISBibTeXText

PMID: 19033644

DOI: 10.1088/0031-9155/53/24/007


Related references

Magnetization transfer imaging for polymer gel dosimetry. Physics in Medicine & Biology 47(11): 1881-1890, 7 June, 2002

Studies of magnetization transfer and relaxation in irradiated polymer gels: Interpretation of MRI-based dosimetry. Physics in Medicine & Biology 46(3): 799-811, March, 2001

The use of polymer gel dosimetry to measure dose distribution around metallic implants. Nihon Hoshasen Gijutsu Gakkai Zasshi 70(10): 1160-1165, 2014

Polymer gel dosimetry--the dose response for X-ray irradiation. Igaku Butsuri 31(3): 75-83, 2013

The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach. Medical Physics 35(5): 1756-1769, 2008

Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry. Reports of Practical Oncology and RadioTherapy 17(3): 146-150, 2012

Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification. Physics in Medicine and Biology 58(18): 6241-6262, 2014

Three dimensional dose distributions from shielded cylindrical high dose rate applicators using band polymer gel dosimetry. International Journal of Radiation Oncology Biology Physics 36(1 SUPPL ): 402, 1996

Proportion of lifetime UV dose received by children, teenagers and adults based on time-stamped personal dosimetry. Journal of Investigative Dermatology 123(6): 1147-1150, 2004

Magnetization transfer imaging provides a quantitative measure of chondrogenic differentiation and tissue development. Tissue Engineering. Part C, Methods 16(6): 1407-1415, 2011

Dispersion in magnetization transfer contrast at a given specific absorption rate due to variations of RF pulse parameters in the magnetization transfer preparation. Magnetic Resonance In Medicine. 37(6): 957-962, E, 1997

Minimizing the effects of magnetization transfer asymmetry on inhomogeneous magnetization transfer (ihMT) at ultra-high magnetic field (11.75 T). Magma 29(4): 699-709, 2016

TO5 as a magnetization transfer contrast test object: characterization of the gels and determination of the real magnetization transfer. Magma 4(3-4): 195-204, 1996