Misoperation of CT automatic tube current modulation systems with inappropriate patient centering: phantom studies



Misoperation of CT automatic tube current modulation systems with inappropriate patient centering: phantom studies



Ajr. American Journal of Roentgenology 192(4): 862-865



Inappropriate patient centering on the gantry changes the size of the localizer radiographs used for CT examinations, influencing the operation of CT automatic tube current modulation because tube current is controlled with information from localizer radiographs. The purpose of this study was to examine the influence of inappropriate patient centering on the gantry isocenter on automatic tube current modulation. An elliptical phantom was scanned with four automatic tube current modulation techniques after acquisition of localizer radiographs in the horizontal and vertical directions with the phantom center shifted from the gantry isocenter in the vertical direction. After scanning, the magnification rate of the frontal localizer radiographs, tube current-time product, and image noise were examined. On phantom studies, the magnification rate of localizer radiographs showed a linear relation to the vertical deviation of the phantom from the gantry isocenter. From 50 mm above to 50 mm below the gantry isocenter, tube current-time products ranged from 75% to 141% compared with those at the gantry isocenter. In addition, increases and decreases in the amount of image noise related to changes in tube current-time product were confirmed. Inappropriate patient centering causes misoperation of automatic tube current modulation systems, in which tube current is controlled with information from localizer radiographs, and thus causes increases in tube current or image noise.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 054399460

Download citation: RISBibTeXText

PMID: 19304687

DOI: 10.2214/ajr.08.1472


Related references

Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study. Ajr. American Journal of Roentgenology 190(2): W100-W105, 2008

Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study. Ajr. American Journal of Roentgenology 184(2): 491-496, 2005

Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: phantom and clinical studies. Radiology 235(2): 523-529, 2005

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997, 2009

Relationships between patient size, dose and image noise under automatic tube current modulation systems. Journal of Radiological Protection 34(1): 103-123, 2014

Evaluating the impact of scan settings on automatic tube current modulation in CT using a novel phantom. British Journal of Radiology 90(1069): 20160308, 2017

A CONSORT-compliant prospective randomized controlled trial: radiation dose reducing in computed tomography using an additional lateral scout view combined with automatic tube current modulation: Phantom and patient study. Medicine 96(30): E7324, 2017

Assessment of image quality on effects of varying tube voltage and automatic tube current modulation with hybrid and pure iterative reconstruction techniques in abdominal/pelvic CT: a phantom study. Investigative Radiology 48(3): 167-174, 2013

Comparison of different phantom designs for CT scanner automatic tube current modulation system tests. Journal of Radiological Protection 33(4): 735-761, 2013

Effect of arm position, presence of medical devices, and off-centering during acquisition of scout image on automatic tube voltage selection and current modulation in pediatric chest CT. Plos one 13(4): E0195807, 2018

A study of CT dose distribution in an elliptical phantom and the influence of automatic tube current modulation in the x-y plane. Journal of Radiological Protection 33(2): 461-483, 2013

Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom. European Journal of Radiology 72(1): 181-187, 2009

Metallic prosthesis: technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients. Radiology 236(2): 671-675, 2005

Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study. European Journal of Radiology 85(9): 1666-1672, 2016

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. Journal of X-Ray Science and Technology 21(4): 453-464, 2013