Multicenter experience with extraction of the Riata/Riata ST ICD lead



Multicenter experience with extraction of the Riata/Riata ST ICD lead



Heart Rhythm 11(9): 1613-1618



In November 2011, the Food and Drug Administration issued a class I recall of Riata and Riata ST implantable cardioverter-defibrillator leads. Management recommendations regarding the recall have remained controversial. Data regarding the safety and feasibility of extraction of Riata implantable cardioverter-defibrillator leads are limited. We performed a retrospective study of patients undergoing extraction of Riata/Riata ST leads at 11 centers. Between July 2003 and April 2013, 577 Riata/Riata ST leads were extracted from 577 patients (Riata 467, [84%]; Riata ST 89, [16%]). Complete procedural success achieved in 99.1%. The cohort was 78% men, with a mean age of 60 years and a mean left ventricular ejection fraction of 34% ± 14%. The mean implant duration was 44.7 months (range 0-124.6 months). The majority of leads extracted were for infection (305 [53.0%]) and 220 (35.7%) for lead malfunction. Evaluation for lead integrity was performed in 295 cases. Of these, 34.9% were found to have externalized cables. Implant duration was significantly longer in leads with externalized cables (P < .0001). No difference in lead integrity was noted between Riata and Riata ST leads (11.7% vs. 17.7% failure; P = .23). Among leads in which cable externalization was noted, laser sheaths were used more frequently (P = .01). Major complications included 3 superior vena cava/right ventricular perforations requiring surgical intervention with 1 death 12 days after the procedure and 1 pericardial effusion requiring percutaneous drainage (0.87%). Extraction of the Riata/Riata ST leads can be challenging, and leads with externalized cables may require specific extraction techniques. Extraction of the Riata/Riata ST leads can be performed safely by experienced operators at high-volume centers with a complication rate comparable to published data.

(PDF emailed within 0-6 h: $19.90)

Accession: 054486195

Download citation: RISBibTeXText

PMID: 24854215

DOI: 10.1016/j.hrthm.2014.05.014


Related references

Prevalence of externalized conductors in Riata and Riata ST silicone leads: results from the prospective, multicenter Riata Lead Evaluation Study. Heart Rhythm 10(12): 1778-1782, 2014

Independent multicenter study of Riata and Riata ST implantable cardioverter-defibrillator leads. Heart Rhythm 10(3): 361-365, 2013

Independent Multicenter Study of Riata and Riata ST ICD Leads. Heart Rhythm 9(9): 1577-1578, 2012

Long-term Electrical Survival Analysis of Riata and Riata ST Silicone Leads—National VA Experience. 2012

Long-term electrical survival analysis of Riata and Riata ST silicone leads: National Veterans Affairs experience. Heart Rhythm 9(12): 1954-1961, 2013

Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads. Heart Rhythm 9(8): 1227-1235, 2013

Falha de integridade dos eltrodos de desfibrilhao Riata e Riata ST: um problema atual. Revista Portuguesa de Cardiologia 32(10): 823-826, 2013

Riata and Riata ST defibrillator leads failure: cable externalization is one problem, but other electrical failures seem more preoccupant. European Heart Journal 34(Suppl 1): P1396-P1396, 2013

National Consultant in Cardiology Experts' Group Guidelines on dealing with patients implanted with some St. Jude Medical Riata and Riata ST leads. Kardiologia Polska 72(6): 576-582, 2016

WikiLeaks of lead extraction: do we know the truth about Fidelis and Riata?. Heart Rhythm 10(10): 1451-1452, 2014

Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads. International Journal of Cardiology 167(1): 254-257, 2014

Conductor externalization of the RIATA implantable cardioverter defibrillator lead: a challenging lead extraction requiring laser-powered sheath. Journal of Cardiovascular Medicine 14(10): 755-756, 2014

Outcomes of Sprint Fidelis and Riata lead extraction: Data from 2 high-volume centers. Heart Rhythm 12(6): 1216-1220, 2016

Combined LASER and femoral approach to remove a previous failure of Riata lead extraction. Clinical Case Reports 5(9): 1459-1461, 2017

The Incidence of Riata Defibrillator Lead Failure: a Single-Center Experience. Journal of Korean Medical Science 32(10): 1610-1615, 2018