Optimization of multi-leaf collimator leaf offset table for a treatment planning system



Optimization of multi-leaf collimator leaf offset table for a treatment planning system



Nihon Hoshasen Gijutsu Gakkai Zasshi 68(2): 173-176



For accurate dose delivery using a rounded leaf-end multi-leaf collimator (MLC), a consistent understanding of MLC leaf offset is required between a linear accelerator (linac) controller and a treatment planning system (TPS). We have found that the leaf offset tables were inconsistent between an Elekta linac controller and a Pinnacle TPS. An optimum leaf offset table for Pinnacle was determined by operating the TPS and the linac controller. It was suggested that the MLC leaf transmission value and the MLC leaf offset table stored in Pinnacle may need to be revised to improve dose verification results for volumetric modulated arc therapy.

(PDF emailed within 0-6 h: $19.90)

Accession: 054773870

Download citation: RISBibTeXText

PMID: 22382625

DOI: 10.6009/jjrt.2012_jsrt_68.2.173



Related references

Optimization of the rounded leaf offset table in modeling the multileaf collimator leaf edge in a commercial treatment planning system. Journal of Applied Clinical Medical Physics 15(6): 4899-4899, 2014

Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization. Medical Physics 29(6): 952-959, 2002

Treatment planning for conformation therapy using a multi-leaf collimator. Strahlentherapie und Onkologie 164(3): 151-154, 1988

Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery. Radiotherapy & Oncology 50(3): 325-336, March, 1999

Use of EPID for leaf position accuracy QA of dynamic multi-leaf collimator (DMLC) treatment. Medical Physics 31(7): 2091-2096, 2004

System and method for optimizing radiation treatment with an intensity modulating multi-leaf collimator. Official Gazette of the United States Patent & Trademark Office Patents 1252(1), Nov 6, 2001

Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning. Japanese Journal of Radiology 35(9): 511-525, 2017

Multi-leaf collimator constrained optimization of intensity modulated treatments. Official Gazette of the United States Patent & Trademark Office Patents 1246(5), May 29, 2001

Physical characterizations for an integrated 160-leaf multi-leaf collimator with a new concept design. Nihon Hoshasen Gijutsu Gakkai Zasshi 69(7): 778-783, 2013

An analytical approach for optimizing the leaf design of a multi-leaf collimator in a linear accelerator. Physics in Medicine and Biology 53(11): 3007-3021, 2008

Physical Characterization of a New Concept Design of an Elekta Radiation Head with Integrated 160-leaf Multi-leaf Collimator. International Journal of Radiation Oncology*biology*physics 75(3): S722-S723, 2009

Impact of Multi-leaf Collimator Leaf Width on Quantitative Dosimetry of Stereotactic Body Radiation Therapy Plans. International Journal of Radiation Oncology*biology*physics 72(1): S621-S622, 2008

Multi-leaf collimator and medical system including accelerator. Official Gazette of the United States Patent & Trademark Office Patents 1286(2), Sep 14, 2004

Performance of a multi leaf collimator system for MR-guided radiation therapy. Medical Physics 44(12): 6504-6514, 2017

A Variable Circular Collimator: A Time-efficient Alternative for a Multi-leaf Collimator in Robotic Radiosurgery?. International Journal of Radiation Oncology*biology*physics 75(3): S674-S675, 2009