+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7 T



Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7 T



Neuroimage 62(3): 2140-2150



One of the promises of Ultra High Field (UHF) MRI scanners is to bring finer spatial resolution in the human brain images due to an increased signal to noise ratio. However, at such field strengths, the spatial non-uniformity of the Radio Frequency (RF) transmit profiles challenges the applicability of most MRI sequences, where the signal and contrast levels strongly depend on the flip angle (FA) homogeneity. In particular, the MP-RAGE sequence, one of the most commonly employed 3D sequences to obtain T1-weighted anatomical images of the brain, is highly sensitive to these spatial variations. These cause deterioration in image quality and complicate subsequent image post-processing such as automated tissue segmentation at UHF. In this work, we evaluate the potential of parallel-transmission (pTx) to obtain high-quality MP-RAGE images of the human brain at 7 T. To this end, non-selective transmit-SENSE pulses were individually tailored for each of 8 subjects under study, and applied to an 8-channel transmit-array. Such RF pulses were designed both for the low-FA excitation train and the 180° inversion preparation involved in the sequence, both utilizing the recently introduced k(T)-point trajectory. The resulting images were compared with those obtained from the conventional method and from subject-specific RF-shimmed excitations. In addition, four of the volunteers were scanned at 3 T for benchmarking purposes (clinical setup without pTx). Subsequently, automated tissue classification was performed to provide a more quantitative measure of the final image quality. Results indicated that pTx could already significantly improve image quality at 7 T by adopting a suitable RF-Shim. Exploiting the full potential of the pTx-setup, the proposed k(T)-point method provided excellent inversion fidelity, comparable to what is commonly only achievable at 3 T with energy intensive adiabatic pulses. Furthermore, the cumulative energy deposition was simultaneously reduced by over 40% compared to the conventional adiabatic inversions. Regarding the low-FA k(T)-point based excitations, the FA uniformity achieved at 7 T surpassed what is typically obtained at 3 T. Subsequently, automated white and gray matter segmentation not only confirmed the expected improvements in image quality, but also suggests that care should be taken to properly account for the strong local susceptibility effects near cranial cavities. Overall, these findings indicate that the k(T)-point-based pTx solution is an excellent candidate for UHF 3D imaging, where patient safety is a major concern due to the increase of specific absorption rates.

(PDF emailed within 0-6 h: $19.90)

Accession: 054860911

Download citation: RISBibTeXText

PMID: 22659484

DOI: 10.1016/j.neuroimage.2012.05.068


Related references

Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging. Ajnr. American Journal of Neuroradiology 30(5): 923-929, 2009

Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases. Acta Radiologica 49(10): 1167-1173, 2008

Pelvic adenopathy in prostatic and urinary bladder carcinoma: MR imaging with a three-dimensional TI-weighted magnetization-prepared-rapid gradient-echo sequence. Ajr. American Journal of Roentgenology 167(6): 1503-1507, 1996

Visualization of the IXth to XIIth cranial nerves using 3-dimensional constructive interference in steady state, 3-dimensional magnetization-prepared rapid gradient echo and T2-weighted 2-dimensional turbo spin echo magnetic resonance imaging sequences. Journal of Neuroimaging 11(2): 160-164, 2001

Parallel-transmission-enabled three-dimensional T2 -weighted imaging of the human brain at 7 Tesla. Magnetic Resonance in Medicine 73(6): 2195-2203, 2016

Magnetization prepared rapid gradient-echo (MP-RAGE) MR imaging of the liver: comparison with spin-echo imaging. Magnetic Resonance Imaging 9(4): 469-476, 1991

Rapid high-resolution three-dimensional mapping of T1 and age-dependent variations in the non-human primate brain using magnetization-prepared rapid gradient-echo (MPRAGE) sequence. Neuroimage 56(3): 1154-1163, 2011

Staging urinary bladder cancer: value of T1-weighted three-dimensional magnetization prepared-rapid gradient-echo and two-dimensional spin-echo sequences. Ajr. American Journal of Roentgenology 164(1): 109-115, 1995

Body diffusion-weighted imaging using magnetization prepared single-shot fast spin echo and extended parallel imaging signal averaging. Magnetic Resonance in Medicine 79(6): 3032-3044, 2017

Shuffled magnetization-prepared multicontrast rapid gradient-echo imaging. Magnetic Resonance in Medicine 79(1): 62-70, 2017

Rapid T1 estimation using tagged magnetization-prepared gradient-echo MR imaging. Magnetic Resonance in Medicine 26(2): 377-385, 1992

Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magnetic Resonance in Medicine 15(1): 152-157, 1990

Tracking motion with tagged rapid gradient-echo magnetization-prepared MR imaging. Journal of Magnetic Resonance Imaging 2(2): 155-163, 1992

Improved efficiency in 2DFT magnetization-prepared rapid gradient echo imaging: application to abdominal imaging. Magnetic Resonance in Medicine 25(1): 195-203, 1992

Carotid magnetization-prepared rapid acquisition with gradient-echo signal is associated with acute territorial cerebral ischemic events detected by diffusion-weighted MRI. Circulation. Cardiovascular Imaging 5(3): 376-382, 2012