+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Percutaneous transcatheter valve-in-valve implantation with the balloon-expandable valve for the treatment of a dysfunctional tricuspid bioprosthetic valve: a pediatric case report



Percutaneous transcatheter valve-in-valve implantation with the balloon-expandable valve for the treatment of a dysfunctional tricuspid bioprosthetic valve: a pediatric case report



Journal of Invasive Cardiology 25(6): 310-312



An inverted Edwards SAPIEN 23 mm valve was implanted in a 14-year-old patient with Ebstein's anomaly who received a Medtronic Mosaic 25 mm valve 8 years earlier and presented with significant progressive symptoms related to severe valvular regurgitation and moderate stenosis. The procedure was performed via the femoral vein using the RetroFlex 3 system and predilatation of the tricuspid valve, under transesophageal echocardiographic guidance. The patient had an immediate drop in right atrial and trans-tricuspid pressures with mild regurgitation, and had stable results on short-term follow-up.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 054922979

Download citation: RISBibTeXText

PMID: 23735360


Related references

Transcatheter Tricuspid Valve-In-Valve Implantation in Patients with Tricuspid Bioprosthetic Valve Degeneration at High Surgical Risk: A Multicenter Case Series. Israel Medical Association Journal 19(3): 156-159, 2017

Transcatheter Tricuspid Valve-in-Valve Implantation for the Treatment of Dysfunctional Surgical Bioprosthetic Valves: An International, Multicenter Registry Study. Circulation 133(16): 1582-1593, 2016

Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up). Journal of Cardiovascular and Thoracic Research 9(3): 152-157, 2017

Percutaneous Valve in Valve Implantation for Dysfunctional Bioprosthetic Valves: A Case Report. A and a Case Reports 9(8): 227-232, 2017

Valve-in-valve implantation with a 23-mm balloon-expandable transcatheter heart valve for the treatment of a 19-mm stentless bioprosthesis severe aortic regurgitation using a strategy of "extreme" underfilling. Catheterization and Cardiovascular Interventions 84(3): 503-508, 2014

Transfemoral valve-in-valve implantation for degenerated bioprosthetic aortic valves using the new balloon-expandable Edwards Sapien 3 valve. Catheterization and Cardiovascular Interventions 88(4): 636-643, 2016

Transatrial transcatheter tricuspid valve-in-valve implantation of balloon expandable bioprosthesis. Annals of Thoracic Surgery 90(5): 1696-1697, 2010

Cusp thrombosis of a self-expandable sutureless aortic valve treated by valve-in-valve transcatheter aortic valve implantation procedure: case report. European Heart Journal. Case Reports 2(4): Yty117, 2018

Transcatheter valve-in-valve implantation for failed bioprosthetic aortic valve: a case report. Zhonghua Xin Xue Guan Bing Za Zhi 41(9): 800-801, 2013

Open transcatheter tricuspid balloon expandable valve-in-valve implantation for failed bioprosthesis. Journal of Thoracic and Cardiovascular Surgery 146(1): E3-E5, 2013

Transvenous transcatheter valve-in-valve implantation after bioprosthetic tricuspid valve failure. Texas Heart Institute Journal 41(5): 507-510, 2014

"Buddy wire" technique in transcatheter aortic valve implantation with a balloon-expandable valve: A rescue option in the setting of direct valve implantation (without predilation). Archivos de Cardiologia de Mexico 86(2): 180-182, 2018

Fracturing a dysfunctional Edwards Perimount bioprosthetic valve to facilitate percutaneous valve-in-valve placement of SAPIEN 3 valve with modified delivery system. Catheterization and Cardiovascular Interventions 91(1): 81-85, 2018

First-in-human valve-in-valve implantation of a 20 mm balloon expandable transcatheter heart valve. Catheterization and Cardiovascular Interventions 82(7): E929-E931, 2013

Valve-in-Valve Transcatheter Aortic Valve Implantation in an Elderly Patient for Degenerated Bioprosthetic Heart Valve. The American Journal of Cardiology 121(8): e153-e154, 2018