Physical activity measured by physical activity monitoring system correlates with glucose trends reconstructed from continuous glucose monitoring



Physical activity measured by physical activity monitoring system correlates with glucose trends reconstructed from continuous glucose monitoring



Diabetes Technology & Therapeutics 15(10): 836-844



In type 1 diabetes mellitus (T1DM), physical activity (PA) lowers the risk of cardiovascular complications but hinders the achievement of optimal glycemic control, transiently boosting insulin action and increasing hypoglycemia risk. Quantitative investigation of relationships between PA-related signals and glucose dynamics, tracked using, for example, continuous glucose monitoring (CGM) sensors, have been barely explored. In the clinic, 20 control and 19 T1DM subjects were studied for 4 consecutive days. They underwent low-intensity PA sessions daily. PA was tracked by the PA monitoring system (PAMS), a system comprising accelerometers and inclinometers. Variations on glucose dynamics were tracked estimating first- and second-order time derivatives of glucose concentration from CGM via Bayesian smoothing. Short-time effects of PA on glucose dynamics were quantified through the partial correlation function in the interval (0, 60 min) after starting PA. Correlation of PA with glucose time derivatives is evident. In T1DM, the negative correlation with the first-order glucose time derivative is maximal (absolute value) after 15 min of PA, whereas the positive correlation is maximal after 40-45 min. The negative correlation between the second-order time derivative and PA is maximal after 5 min, whereas the positive correlation is maximal after 35-40 min. Control subjects provided similar results but with positive and negative correlation peaks anticipated of 5 min. Quantitative information on correlation between mild PA and short-term glucose dynamics was obtained. This represents a preliminary important step toward incorporation of PA information in more realistic physiological models of the glucose-insulin system usable in T1DM simulators, in development of closed-loop artificial pancreas control algorithms, and in CGM-based prediction algorithms for generation of hypoglycemic alerts.

(PDF emailed within 0-6 h: $19.90)

Accession: 054993386

Download citation: RISBibTeXText

PMID: 23944973

DOI: 10.1089/dia.2013.0105



Related references

Subcutaneous continuous glucose monitoring system in assessment of a dynamics of the glycemia during and after physical activity in patients with diabetes. Nutrition 24(6): 614-0, 2008

Nocturnal Hypoglycemia and Physical Activity in Children With Diabetes: New Insights by Continuous Glucose Monitoring and Accelerometry. Diabetes Care 39(7): E95-E96, 2016

Day-to-day glucose variability during pregnancy in women with Type 1 diabetes mellitus: glucose profiles measured with the Continuous Glucose Monitoring System. Bjog 111(9): 919-924, 2004

Increased 72 hour glucose concentration measured by continuous glucose monitoring system in normal glucose tolerant patients with pancreas transplantation. 2007

Daily glucose variation measured by continuous glucose monitoring system in normal glucose tolerant patients with pancreas transplantation as compared to healthy controls. 2007

Influence of rich and low carbohydrate diet on glucose level and glucose peaks in gestational diabetics measured by the Continuous Glucose Monitoring System ; Minimed Medtronic. Diabetologia 45(Supplement 2): A 296, August, 2002

Continuous glucose monitoring counseling improves physical activity behaviors of individuals with type 2 diabetes: A randomized clinical trial. Diabetes Research and Clinical Practice 80(3): 371-379, 2008

Acceptability of Continuous Glucose Monitoring in Free-Living Healthy Individuals: Implications for the Use of Wearable Biosensors in Diet and Physical Activity Research. Jmir Mhealth and Uhealth 6(10): E11181-E11181, 2018

A continuous glucose monitoring and problem-solving intervention to change physical activity behavior in women with type 2 diabetes: a pilot study. Diabetes Technology & Therapeutics 13(11): 1091-1099, 2012

Comparative assessment of glucose prediction models for patients with type 1 diabetes mellitus applying sensors for glucose and physical activity monitoring. Medical & Biological Engineering & Computing 53(12): 1333-1343, 2016

Continuous glucose monitoring system versus self-monitoring blood glucose in order to improve night-time glucose profile in subjects with Type 1 diabetes The NOCTURNO study. Diabetes & Metabolism 29(Hors serie 2): 4S196, August, 2003

Continuous glucose monitoring system during physical exercise in adolescents with type 1 diabetes. Acta Paediatrica 100(12): 1603-1609, 2012

Comparison of glucose fluctuations between day- and night-time measured using a continuous glucose monitoring system in diabetic dogs. Journal of Veterinary Medical Science 75(1): 113-117, 2013

Efficacy of continuous real-time blood glucose monitoring during and after prolonged high-intensity cycling exercise: spinning with a continuous glucose monitoring system. Diabetes Technology & Therapeutics 8(6): 627-635, 2006

Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System. Diabetes Technology & Therapeutics 11(3): 145-150, 2009