+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Physiological assessment of active middle ear implant coupling to the round window in Chinchilla lanigera



Physiological assessment of active middle ear implant coupling to the round window in Chinchilla lanigera



Otolaryngology--Head and Neck Surgery 145(4): 641-647



To study the effects of various active middle ear implant loading parameters on round window stimulation in an animal model. Physiological measurements of the cochlear microphonic and stapes velocity were made from active middle ear implant-generated sinusoidal stimuli with controlled changes in loading parameters. Prospective study at an academic research institution. Cochlear microphonic and stapes velocities (H(EV)) were measured in 6 study subjects (Chinchilla lanigera) in response to active middle ear implant (Otologics MET, Boulder, Colorado) round window stimulation with assessment of effects of varying parameters of loading pressure, interposed connective tissue, and angle of stimulation with respect to the round window membrane. The measured performance variabilities in repeated applications of the active middle ear implant to the round window were 2.5 dB and 5.0 dB for H(EV) and cochlear microphonic thresholds, respectively. Loading pressure applied to the round window (51-574 dynes) and angle of approach (±30° with respect to coronal plane) did not have a significant effect on cochlear microphonic thresholds or H(EV). Significant improvements in cochlear microphonic thresholds and H(EV) were observed for interposed connective tissue regardless of tissue type. Variability in performance due to repeated couplings of the active middle ear implant to the round window is small and reproducible. Interposition of connective tissue significantly improves vibration energy transfer to the cochlea. Neither changes in loading pressure nor angle of stimulation of the round window affected active middle ear implant performance.

(PDF emailed within 0-6 h: $19.90)

Accession: 055001373

Download citation: RISBibTeXText

PMID: 21593462

DOI: 10.1177/0194599811409674


Related references

Third-window vibroplasty with an active middle ear implant: assessment of physiologic responses in a model of stapes fixation in Chinchilla lanigera. Otology & Neurotology 33(3): 425-431, 2012

Round window membrane implantation with an active middle ear implant: a study of the effects on the performance of round window exposure and transducer tip diameter in human cadaveric temporal bones. Audiology & Neuro-Otology 15(5): 291-302, 2010

Round window application of an active middle ear implant (AMEI) system in congenital oval window atresia. Acta Oto-Laryngologica 136(1): 23-33, 2016

Round Window Application of an Active Middle Ear Implant. Otology & Neurotology 38(6): E145-E151, 2017

Megaesophagus in a chinchilla Chinchilla lanigera A case report Megaoesophagus bei einem Chinchilla Chinchilla lanigera Ein Fallbericht. Tieraerztliche Praxis Ausgabe K Kleintiere Heimtiere, 322: 96-100, 2004

Case Report of a New Coupler for Round Window Application of an Active Middle Ear Implant. Otology & Neurotology, 2018

Round Window Application of an Active Middle Ear Implant: A Comparison With Hearing Aid Usage in Japan. Otology & Neurotology 38(6): E145-E151, 2017

Active middle ear implant coupled bilaterally to the round window despite bilateral implanted stapes prostheses. Laryngoscope 127(2): 500-503, 2016

Is the Bone-Conduction HeadBand test useful for predicting the functional outcome of a round window active middle ear implant?. Otology & Neurotology 34(7): 1329-1335, 2014

Impact of coupling techniques of an active middle ear device to the round window membrane for the backward stimulation of the cochlea. Otology & Neurotology 36(1): 111-117, 2015

Preservation of chinchilla genital system Chinchilla lanigera for microscopic evaluation Preservacao do sistema genital de chinchila Chinchilla lanigera para avaliacao em microscopia de luz. Arquivo Brasileiro de Medicina Veterinaria e Zootecnia. December; 586: 1247-1248, 2006

Electrocochleographic and mechanical assessment of round window stimulation with an active middle ear prosthesis. Hearing Research 263(1-2): 128-137, 2010

Eye diseases of Chinchilla (Chinchilla lanigera): anatomical and physiological characteristics and disorders. 2008

Systematization, distribution and territory of the middle cerebral artery on the brain surface in chinchilla (Chinchilla lanigera). Anatomia, Histologia, Embryologia 38(1): 12-17, 2008

Cost-benefit relationship in thermoregulation of Chinchilla lanigera Relacion costo-beneficio en la termorregulacion de Chinchilla lanigera. Revista Chilena de Historia Natural. Junio; 732: 351-357, 2000