Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach



Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach



Artificial Organs 38(9): 766-774



Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow during exercise without causing pulmonary venous congestion.

(PDF emailed within 0-6 h: $19.90)

Accession: 055001588

Download citation: RISBibTeXText

PMID: 24749848

DOI: 10.1111/aor.12303


Related references

Jarvik 2000 biventricular assist device conversion from old pin-shaped bearing pumps to new conical bearing pumps. Journal of Artificial Organs 16(1): 105-109, 2013

Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device. Journal of Thoracic and Cardiovascular Surgery 137(4): 971-977, 2009

The BiVACOR rotary biventricular assist device: concept and in vitro investigation. Artificial Organs 32(10): 816-819, 2008

Investigation of the methods of controlling the biventricular assist device with continuous flow pumps. The motor current amplitude of left ventricular assist devices determines the flow rate of right ventricular assist devices (RVAD). Japanese Journal of Artificial Organs 29(1): 51-56, 2000

Two axial-flow Synergy Micro-Pumps as a biventricular assist device in an ovine animal model. Journal of Heart and Lung Transplantation 31(11): 1223-1229, 2013

Long-term left ventricle assist device (LVAD) therapy with rotary pumps. Scandinavian Cardiovascular Journal 43(6): 357-359, 2010

Over 1200-day support with dual Jarvik 2000 biventricular assist device. Interactive Cardiovascular and Thoracic Surgery 19(6): 1083-1084, 2016

Clinical report of long-term support with dual Jarvik 2000 biventricular assist device. Journal of Heart and Lung Transplantation 30(7): 845-847, 2011

A novel control framework for nonlinear time-delayed dual-master/single-slave teleoperation. Isa Transactions 52(2): 268-277, 2013

Novel approach to management of acute pulmonary failure during biventricular assist device insertion. Journal of Heart and Lung Transplantation 28(1): 107-109, 2009

In Vitro Evaluation of the Dual-Diffuser Design for a Reversible Rotary Intra-Aortic Ventricular Assist Device. Artificial Organs 40(9): 884-893, 2016

A right thoracotomy approach for the cannulations of biventricular assist device - A preclinical cadaver fitting trial. International Journal of Artificial Organs 23(8): 553, August, 2000

Passive control of a biventricular assist device with compliant inflow cannulae. Artificial Organs 36(8): 683-690, 2012

Pheochromocytoma presenting as severe biventricular failure requiring insertion of a biventricular assist device. Journal of Cardiothoracic and Vascular Anesthesia 24(6): 985-987, 2011

Biventricular cannulation is superior regarding hemodynamics and organ recovery in patients on biventricular assist device support. Journal of Heart and Lung Transplantation 30(9): 1011-1017, 2012