+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Physiological monitoring in firefighter ensembles: wearable plethysmographic sensor vest versus standard equipment



Physiological monitoring in firefighter ensembles: wearable plethysmographic sensor vest versus standard equipment



Journal of Occupational and Environmental Hygiene 7(2): 109-114



We evaluated the accuracy of a wearable sensor vest for real-time monitoring of physiological responses to treadmill exercise. Ten subjects in standard firefighter ensembles, treadmill exercising at 50% VO(2) max, had heart rate (HR), respiratory rate (RR), skin temperature (T(sk)), oxygen saturation (SaO(2)), tidal volume (V(T)), and minute ventilation (V(E)) recorded concurrently by a wearable plethysmographic sensor vest and standard laboratory physiological monitoring equipment for comparison. A high degree of correlation was noted for most of the measured variables [HR (r = 0.99), RR (r = 0.98), T(sk) (r = 0.98), V(E) (r = 0.88), and SaO(2) (r = 0.79)]. V(T) (r = 0.60) had a moderate correlation, although a paired differences analysis showed a mean paired difference of -0.03 L. This mean paired difference represents a 1.92% variation for V(T). Data from the wearable sensor vest is comparable to data captured from standard laboratory physiological monitoring equipment on subjects wearing standard firefighter ensembles while exercising at a moderate work rate. This study demonstrates the accuracy of the wearable sensor technology for these physiological parameters under these conditions and suggests that it could be useful for actual field studies of firefighters in traditional firefighting gear.

(PDF emailed within 0-6 h: $19.90)

Accession: 055002056

Download citation: RISBibTeXText

PMID: 20017053

DOI: 10.1080/15459620903455722


Related references

The design of a wearable ECG and respiration sensor vest and its monitoring system. Zhongguo Yi Liao Qi Xie Za Zhi 30(5): 341-344, 2006

Smart Vest: wearable multi-parameter remote physiological monitoring system. Medical Engineering and Physics 30(4): 466-477, 2007

A wearable physiological sensor suite for unobtrusive monitoring of physiological and cognitive state. Conference Proceedings 2007: 5276-5281, 2007

Wearable wireless multi-parameter sensor module for physiological monitoring. Studies in Health Technology and Informatics 177: 210-215, 2012

Smartwatch-based driver alertness monitoring with wearable motion and physiological sensor. Conference Proceedings 2015: 6126-6129, 2016

A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction. Biosensors 5(2): 288-307, 2016

Cable-free wearable sensor system using a DC powerline body network in a conductive fabric vest. Conference Proceedings 7: 5376-5379, 2007

A novel wearable apnea dive computer for continuous plethysmographic monitoring of oxygen saturation and heart rate. Diving and Hyperbaric Medicine 40(1): 34-40, 2010

Detection of physiological deterioration by the SNAP40 wearable device compared to standard monitoring devices in the emergency department: the SNAP40-ED study. Diagnostic and Prognostic Research 2: 18, 2019

Development of a Wearable Instrumented Vest for Posture Monitoring and System Usability Verification Based on the Technology Acceptance Model. Sensors 16(12), 2018

Comparison of a wearable polysomnograph with standard laboratory polysomnographic equipment. Sleep 24(Abstract Supplement): A402, April 15, 2001

Vest for the physiological monitoring of children. Official Gazette of the United States Patent & Trademark Office Patents 1189(4): 2534, Aug 27, 1996

Evaluation of a new ballistic vest design for compliance with Standard No. PN-V-87000:2011 using physiological tests. International Journal of Occupational Safety and Ergonomics 2018: 1-10, 2018

Monitoring smoking behaviour using a wearable acoustic sensor. Conference Proceedings 2017: 4459-4462, 2018

Functional activity monitoring from wearable sensor data. Conference Proceedings 2: 979-982, 2007