+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Pre-implantation electrochemical characterization of a Parylene C sheath microelectrode array probe



Pre-implantation electrochemical characterization of a Parylene C sheath microelectrode array probe



Conference Proceedings 2012: 5126-5129



We present the preliminary electrochemical characterization of 3D Parylene C sheath microelectrode array probes towards realizing reliable chronic neuroprosthetic recordings. Electrochemical techniques were used to verify electrode integrity after our novel post-fabrication thermoforming process was applied to flat surface micromachined structures to achieve a hollow sheath probe shape. Characterization of subsequent neurotrophic coatings was performed and accelerated life testing was used to simulate six months in vivo. Prior to probe implantation, crosstalk was measured and electrode surface properties were evaluated through the use of electrochemical impedance spectroscopy.

(PDF emailed within 0-6 h: $19.90)

Accession: 055092234

Download citation: RISBibTeXText

PMID: 23367082

DOI: 10.1109/EMBC.2012.6347147


Related references

A Parylene-Based Microelectrode Array Implant For Spinal Cord Stimulation In Rats. Conference Proceedings 2011: 1007-1010, 2011

Biocompatibility of subretinal parylene-based Ti/Pt microelectrode array in rabbit for further artificial vision studies. Journal of Ocular Biology, Diseases, and Informatics 2(1): 33-36, 2010

3D Parylene sheath neural probe for chronic recordings. Journal of Neural Engineering 10(4): 045002-045002, 2014

Ordered polymeric microhole array made by selective wetting and applications for electrochemical microelectrode array. Langmuir 27(13): 8548-8553, 2011

Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration. Lab on A Chip 13(4): 554-561, 2013

A new multi-site probe array with monolithically integrated parylene flexible cable for neural prostheses. Conference Proceedings 7: 7114-7117, 2007

An addressable microelectrode array for electrochemical detection. Analytical Chemistry 80(17): 6830-6833, 2008

Multichannel electrochemical detection with a microelectrode array in flowing streams. Analytical Chemistry 64(1): 44-49, 1992

Soft microelectrode linear array for scanning electrochemical microscopy. Analytical Chemistry 82(24): 10037-10044, 2011

Electrochemical topography of a cell monolayer with an addressable microelectrode array. Chemical Communications 46(4): 559-561, 2010

Long-term reliability of Al2O3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation. Journal of Neural Engineering 11(2): 026016-026016, 2014

An electrochemical immunosensor based on interdigitated array microelectrode for the detection of chlorpyrifos. Bioprocess and Biosystems Engineering 38(2): 307-313, 2015

Signal-to-noise ratio in microelectrode-array-based electrochemical detectors. Analytical Chemistry 61(4): 295-302, 1989

A floating metal microelectrode array for chronic implantation. Journal of Neuroscience Methods 160(1): 122-127, 2006

Use of a Carbon-ink Microelectrode Array for Signal Enhancement in Microchip Electrophoresis with Electrochemical Detection. Electroanalysis 22(19): 2141-2146, 2011