Prevalence of externalized conductors in Riata and Riata ST silicone leads: results from the prospective, multicenter Riata Lead Evaluation Study



Prevalence of externalized conductors in Riata and Riata ST silicone leads: results from the prospective, multicenter Riata Lead Evaluation Study



Heart Rhythm 10(12): 1778-1782



Following a class I recall of St. Jude Medical Riata/Riata ST silicone implantable cardioverter-defibrillator leads, we report on the phase I results of the Riata Lead Evaluation Study, a prospective, multicenter investigation to assess the prevalence of externalized conductors (ECs) and the electrical dysfunction in these leads. We enrolled patients previously implanted with Riata/Riata ST leads and performed cinefluoroscopy using multiple views. A physician panel adjudicated the images for the presence of EC. The prevalence of EC was stratified and compared by lead model and patient characteristics. Upon occurrence of a lead revision, another physician panel determined whether electrical dysfunction had occurred based on predefined criteria. Seven hundred seventy six patients with Riata/Riata ST silicone leads (8Fr/7Fr = 66.6%/33.4%; single-/dual-coil = 12.9%/87.1%) across 23 centers were analyzed. Implant duration was 4.8 ± 0.9 years for 7Fr and 6.5 ± 1.6 years for 8Fr leads (P <.001). The prevalence of EC was significantly lower in 7Fr compared with 8Fr leads for the entire study population (9.3% vs 24.2%, P < .001) and for leads implanted ≤6 years (9.4% vs 18.8%, P = .006). Other than lead size, there were no significant differences in lead, patient, or electrical characteristics between leads with and without EC. Over a period of 9.8 ± 2.0 months, the overall prevalence of electrical dysfunction was 1.3% (confidence interval 0.49%-2.1%), with only 3 of 10 cases occurring in leads with EC. Larger-diameter Riata leads were more prone to EC than smaller-diameter Riata ST leads. The prevalence of electrical dysfunction was not associated with EC.

(PDF emailed within 0-6 h: $19.90)

Accession: 055157713

Download citation: RISBibTeXText

PMID: 23994078

DOI: 10.1016/j.hrthm.2013.08.030


Related references

Independent multicenter study of Riata and Riata ST implantable cardioverter-defibrillator leads. Heart Rhythm 10(3): 361-365, 2013

Independent Multicenter Study of Riata and Riata ST ICD Leads. Heart Rhythm 9(9): 1577-1578, 2012

Contribution of ethylenetetrafluoroethylene (ETFE) insulation to the electrical performance of Riata® silicone leads having externalized conductors. Journal of Interventional Cardiac Electrophysiology 37(2): 141-145, 2014

Long-term Electrical Survival Analysis of Riata and Riata ST Silicone Leads—National VA Experience. 2012

Long-term electrical survival analysis of Riata and Riata ST silicone leads: National Veterans Affairs experience. Heart Rhythm 9(12): 1954-1961, 2013

Multicenter experience with extraction of the Riata/Riata ST ICD lead. Heart Rhythm 11(9): 1613-1618, 2015

Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads. International Journal of Cardiology 167(1): 254-257, 2014

Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads. Heart Rhythm 9(8): 1227-1235, 2013

Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee. Circulation. Arrhythmia and Electrophysiology 5(6): 1059-1063, 2013

Riata and Riata ST defibrillator leads failure: cable externalization is one problem, but other electrical failures seem more preoccupant. European Heart Journal 34(Suppl 1): P1396-P1396, 2013

National Consultant in Cardiology Experts' Group Guidelines on dealing with patients implanted with some St. Jude Medical Riata and Riata ST leads. Kardiologia Polska 72(6): 576-582, 2016

Lead thrombi associated with externalized cables on Riata ICD leads: a case series. Journal of Cardiovascular Electrophysiology 24(9): 1047-1050, 2014

Increasing lead burden correlates with externalized cables during systematic fluoroscopic screening of Riata leads. Journal of Interventional Cardiac Electrophysiology 37(1): 63-68, 2014

Failure of fluoroscopy to detect "inside-out" insulation failure and externalized conductors in a Riata ICD lead. Heart Rhythm 10(12): 1827-1828, 2014

Riata externalized conductors: cosmetic defect or manifestation of a more serious design flaw?. Heart Rhythm 9(8): 1225-1226, 2013