+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Pseudocontinuous arterial spin labeling perfusion magnetic resonance imaging--a normative study of reproducibility in the human brain



Pseudocontinuous arterial spin labeling perfusion magnetic resonance imaging--a normative study of reproducibility in the human brain



Neuroimage 56(3): 1244-1250



Pseudocontinuous arterial spin labeling (PCASL), a newly proposed perfusion magnetic resonance imaging (MRI) technique, has the potential of providing a better balance between labeling efficiency and signal-to-noise ratio than conventional ASL methods. The advantage will not be exploitable until adequate reproducibility can be achieved. In this study, we investigated the reproducibility of PCASL on twelve healthy volunteers by taking into account the inclusion of correction for coil sensitivity (CS) and labeling efficiency (α). Each subject underwent two identical sessions scheduled two weeks apart. For comparison, pulsed ASL (PASL) imaging was also conducted using the flow-sensitive alternating inversion recovery method. MR imaging was performed on a 3T whole body system using a 12-channel phased array for reception. Blood flow was quantified for gray matter and assessed globally as well as in the flow territories of the internal carotid arteries and posterior cerebral arteries. Experimental results showed that CS accounted for 35% and 60% of inter-session variability in PCASL and PASL, respectively. With CS correction alone, coefficient of variance (CV) remained larger with PCASL than PASL (p=0.02). CV was 12% with CS-corrected PASL and 11% with PCASL when CS and α were corrected for in conjunction. We concluded that CS correction is necessary for ASL imaging when using phased array receiver and that after CS correction, PCASL requires α correction to provide reproducibility comparable to PASL.

(PDF emailed within 0-6 h: $19.90)

Accession: 055265220

Download citation: RISBibTeXText

PMID: 21385620

DOI: 10.1016/j.neuroimage.2011.02.080


Related references

Comparative evaluation of 3-dimensional pseudocontinuous arterial spin labeling with dynamic contrast-enhanced perfusion magnetic resonance imaging in grading of human glioma. Journal of Computer Assisted Tomography 37(3): 321-326, 2013

Measurement of cerebral white matter perfusion using pseudocontinuous arterial spin labeling 3T magnetic resonance imaging--an experimental and theoretical investigation of feasibility. Plos One 8(12): E82679, 2014

Optimal individual inversion time in brain arterial spin labeling perfusion magnetic resonance imaging: correlation with carotid hemodynamics measured with cine phase-contrast magnetic resonance imaging. Journal of Computer Assisted Tomography 37(2): 247-251, 2013

Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging. Radiology 234(3): 909-916, 2005

Fast imaging strategies for mouse kidney perfusion measurement with pseudocontinuous arterial spin labeling (pCASL) at ultra high magnetic field (11.75 tesla). Journal of Magnetic Resonance Imaging 42(4): 999-1008, 2016

Arterial spin labeling perfusion magnetic resonance imaging of non-human primates. Quantitative Imaging in Medicine and Surgery 6(5): 573-581, 2016

Continuous arterial spin-labeling perfusion magnetic resonance imaging of the human testis. Academic Radiology 11(1): 106-110, 2004

Arterial Spin Labeling Cerebral Perfusion Magnetic Resonance Imaging in Migraine Aura: An Observational Study. Journal of Stroke and Cerebrovascular Diseases 27(5): 1262-1266, 2018

Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla. Bmc Nephrology 15: 23, 2014

Perfusion imaging of cerebral arteriovenous malformations: a study comparing quantitative continuous arterial spin labeling and dynamic contrast-enhanced magnetic resonance imaging at 3 T. Magnetic Resonance Imaging 29(9): 1157-1164, 2012

Magnetic resonance imaging of perfusion with arterial spin labeling. Ishii, Y, Yonekura, Y, Fujibayashi, Y, Sadato, N International Congress Series; Recent advances in biomedical imaging 71-83, 1997

Sensitivity of Multiphase Pseudocontinuous Arterial Spin Labelling (MP pCASL) Magnetic Resonance Imaging for Measuring Brain and Tumour Blood Flow in Mice. Contrast Media & Molecular Imaging 2018: 4580919-4580919, 2018

Functional perfusion imaging using pseudocontinuous arterial spin labeling with low-flip-angle segmented 3D spiral readouts. Magnetic Resonance in Medicine 69(2): 382-390, 2013

Physiological modulations in arterial spin labeling perfusion magnetic resonance imaging. IEEE Transactions on Medical Imaging 28(5): 703-709, 2009

Arterial spin labeling magnetic resonance perfusion imaging in cerebral ischemia. Current Opinion in Neurology 27(1): 42-53, 2014