Quantitative multi-pinhole small-animal SPECT: uniform versus non-uniform Chang attenuation correction



Quantitative multi-pinhole small-animal SPECT: uniform versus non-uniform Chang attenuation correction



Physics in Medicine and Biology 56(18): N183-N193



Attenuation of photon flux on trajectories between the source and pinhole apertures affects the quantitative accuracy of reconstructed single-photon emission computed tomography (SPECT) images. We propose a Chang-based non-uniform attenuation correction (NUA-CT) for small-animal SPECT/CT with focusing pinhole collimation, and compare the quantitative accuracy with uniform Chang correction based on (i) body outlines extracted from x-ray CT (UA-CT) and (ii) on hand drawn body contours on the images obtained with three integrated optical cameras (UA-BC). Measurements in phantoms and rats containing known activities of isotopes were conducted for evaluation. In (125)I, (201)Tl, (99m)Tc and (111)In phantom experiments, average relative errors comparing to the gold standards measured in a dose calibrator were reduced to 5.5%, 6.8%, 4.9% and 2.8%, respectively, with NUA-CT. In animal studies, these errors were 2.1%, 3.3%, 2.0% and 2.0%, respectively. Differences in accuracy on average between results of NUA-CT, UA-CT and UA-BC were less than 2.3% in phantom studies and 3.1% in animal studies except for (125)I (3.6% and 5.1%, respectively). All methods tested provide reasonable attenuation correction and result in high quantitative accuracy. NUA-CT shows superior accuracy except for (125)I, where other factors may have more impact on the quantitative accuracy than the selected attenuation correction.

(PDF emailed within 0-6 h: $19.90)

Accession: 055323207

Download citation: RISBibTeXText

PMID: 21865622

DOI: 10.1088/0031-9155/56/18/N01



Related references

Reliability and advantages of using non-uniform Chang's attenuation correction method using a CT-based attenuation coefficient map in (99m)Tc-GSA SPECT/CT hepatic imaging. Ejnmmi Physics 2(1): 17-17, 2015

Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers. European Journal of Nuclear Medicine 28(1): 90-98, 2001

A non-uniform attenuation correction for quantitative thorax SPECT based on lung emission. Journal of Nuclear Medicine 34(5 SUPPL ): 190P, 1993

Effect of non-uniform attenuation correction on quantitative parameters in simultaneous transmission-emission myocardial gated Tc-99m-MIBI SPECT. Journal of Nuclear Medicine 40(5 SUPPL ): 165P-166P, 1999

CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia. Physics in Medicine and Biology 60(17): 6775-6787, 2016

Non uniform attenuation correction for the heart spect with iterated radial post correction irpc method. Journal of Nuclear Medicine 30(5 SUPPL): 870, 1989

Scatter correction in SPECT using non-uniform attenuation data. Physics in Medicine and Biology 33(10): 1129-1140, 1988

Beacon-Stm: Non-uniform attenuation correction for SPECT imaging. Nuclear Medicine Review. Central & Eastern Europe 2(2): 87-92, 2003

Is non-uniform attenuation correction necessary for clinical brain perfusion SPECT?. Journal of Nuclear Medicine 41(5 Suppl ): 186P, 2000

The limitations of uniform attenuation correction for brain SPECT quantification. Journal of Nuclear Medicine 38(5 SUPPL ): 211P-212P, 1997

Impact of non-uniform attenuation correction and scatter correction on the diagnostic accuracy of myocardial spect for the detection of coronary artery disease A Prospective study. Journal of Nuclear Medicine 43(5 Supplement): 49P, 2002

Improvement of the imaging quality by a non-uniform attenuation correction system in cardiac SPECT. Revista Espanola de Medicina Nuclear 22(5): 306-315, 2003

The use of asymmetric fan-beam collimator and non-uniform attenuation correction in Tc-99m HMPAO brain SPECT. Journal of Nuclear Medicine 40(5 SUPPL ): 283P-284P, 1999

An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction. Physics in Medicine and Biology 51(23): 6199-6211, 2006

An investigation of an efficient projection domain method of non-uniform attenuation correction in SPECT. Journal of Nuclear Medicine 36(5 SUPPL ): 50P, 1995