+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Radiation dose reduction for chest CT with non-linear adaptive filters



Radiation dose reduction for chest CT with non-linear adaptive filters



Acta Radiologica 54(2): 169-174



CT radiation dose reduction results in increased noise or graininess of images which affects the diagnostic information. One of the approaches to lower radiation exposure to patients is to reduce image noise with the use of image processing software in low radiation dose images. To assess image quality and accuracy of non-linear adaptive filters (NLAF) at low dose chest CT. In an IRB approved prospective study, 24 patients (mean age, 63 ± 7.3 years; M:F ratio, 11:13) gave informed consent for acquisition of four additional chest CT image series at 150, 110, 75, and 40 mAs (baseline image series) on a 64-slice MDCT over an identical 10-cm length. NLAF was used to process three low dose (110, 75, and 40 mAs) image series (postprocessed image series). Two radiologists reviewed baseline and postprocessed images in a blinded manner for image quality. Objective noise, CT attenuation values, patient weight, transverse diameters, CTDIvol, and DLP were recorded. Statistical analysis was performed using parametric and non-parametric tests for comparing postprocessed and baseline images. No lesions were missed on baseline or postprocessed CT images (n = 80 lesions, 73 lesions <1 cm). At 40 mAs, subjective noise in mediastinal window settings were graded as unacceptable in baseline images and acceptable in postprocessed images. Visibility of smaller structures improved from suboptimal visibility in baseline images at 40 mAs to excellent in postprocessed images at 40 mAs. No major artifacts were seen due to NLAF postprocessing, except for minor beam hardening artifacts not affecting diagnostic decision-making (14/22) in both baseline and postprocessed image series. Diagnostic confidence for chest CT was improved to fully confident in postprocessed images at 40 mAs. Compared to baseline images, postprocessing reduced objective noise by 26% (14.2 ± 4.7/19.2 ± 6.4), 31.5% (15.2 ± 4.7/22.2 ± 5.7), and 41.5% (16.9 ± 6/28.9 ± 10.2) at 110 mAs, 75 mAs, and 40 mAs tube current-time product levels. Applications of NLAF can help reduce tube current down to 40 mAs for chest CT while maintaining lesion conspicuity and image quality.

(PDF emailed within 0-6 h: $19.90)

Accession: 055343426

Download citation: RISBibTeXText

PMID: 23185071

DOI: 10.1258/ar.2012.120045


Related references

Radiation dose reduction with application of non-linear adaptive filters for abdominal CT. World Journal of Radiology 4(1): 21-28, 2012

Adaptive iterative dose reduction 3D (AIDR 3D) vs. filtered back projection: radiation dose reduction capabilities of wide volume and helical scanning techniques on area-detector CT in a chest phantom study. Acta Radiologica 57(6): 684-690, 2015

Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study. Radiology 228(1): 257-264, 2003

Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques. European Journal of Radiology 81(12): 4185-4195, 2013

Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology 259(2): 565-573, 2011

Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. Journal of Computer Assisted Tomography 34(1): 40-45, 2010

Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: an intra-individual comparison. European Journal of Radiology 81(9): E938-E943, 2013

Adaptive Iterative Dose Reduction Using Three Dimensional Processing (AIDR3D) improves chest CT image quality and reduces radiation exposure. Plos One 9(8): E105735-E105735, 2015

Dose reduction in computed tomography of the chest: image quality of iterative reconstructions at a 50% radiation dose compared to filtered back projection at a 100% radiation dose. Rofo 186(6): 576-584, 2014

Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT. Acta Radiologica 53(3): 335-342, 2012

Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D). International Journal of Cardiovascular Imaging 29(5): 1167-1175, 2014

Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D. International Journal of Cardiovascular Imaging 31(5): 1045-1052, 2016

Adaptive iterative dose reduction in coronary CT angiography using 32-row CT assessment of radiation dose reduction and image quality. 2012

Determining the radiation dose reduction potential for coronary calcium scanning with computed tomography: an anthropomorphic phantom study comparing filtered backprojection and the adaptive iterative dose reduction algorithm for image reconstruction. Investigative Radiology 48(12): 857-862, 2014

Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study. European Journal of Radiology 85(9): 1666-1672, 2016